1700degree C High and low temperature impact test furnace SHLL-1700
Negotiable /Set
Min.Order:1 Set
Shanghai Jinwei Instrument Manufacturing Co., Ltd.
1700degree C High and low temperature impact test furnace
The HLL - 1700 high and low temperature impact test furnace is used to test the rapid conversion trial from 1600 ° C to -60 ° C. High and low temperature zone adopted screw automatic control, the entire conversion process can be complete in a relatively short time. The equipment is divided into three parts of the high temperature zone, the low temperature zone and transition zone. With thermal processing between each zone. Low temperature zone adopted the dual refrigeration system, and the cooling type have air-cooled or water-cooled for selectable.
1. Testing specimen quickly from the hot zone into the low temperature zone, can research material changes in the sudden heat quench, each temperature zone adopted unique isolation technology, independently of each other;
2. The furnace chamber of high temperature zone adopted imported alumina polycrystalline fibers material, with good thermal insulation properties, durability, and heating elements adopted imported silicon molybdenum rod with long service life; Low temperature using a dual refrigeration system to keep a long-term cooling;
3. Automatically operation and control, control systems used multi-step programming to meet a variety of complex test requirements; For remote centralized control we have software for optional purchase;
4. With over-temperature alarm, leakage protection, short circuit protection, compressor overload protection and lack water protection function, used safe and reliable.
Widely used in the research of aerospace materials and the weathering test of special materials.
Model | HLL-1700(Approved by CE certificate, ensure the safety operation of the machine. Certificate No.: GB/1067/4189/12 Issue 1) |
High temperature working zone | 350*350*250mm)(Customizable) |
Low temperature working zone | 320*350*450mm)(Customizable) |
High temperature Thermometric component | B-mode thermocouple |
Low temperature control component | Temperature sensor, humidity sensor |
Cooling system | Two-stage semi-hermetic compressors ( water-cooled ) Fully enclosed two-stage compressor ( air-cooled ) |
Working temperature of High temperature zone | ≤1600℃ |
Working temperature of Low temperature zone | -10℃~-65℃ |
Constant temperature accuracy of High temperature zone | ±1℃ |
Constant temperature accuracy of Low temperature zone | ±0.5℃ |
Humidity range of Low temperature range | 30%-98%R·H (Customizable) |
Temperature response time | ≤20min |
Conversion time | ≤1min |
Rated power | 12KW |
Working power | AC380V /50HZ/60HZ |