Hot Metal Inspection Instrumentation with Rolls Gap Control
Negotiable /Set
Min.Order:1 Set
Moduloc System Engineering Ltd. (Yantai)
Hot Metal Inspection Instrumentation with Rolls Gap Control
1. General Description
The MSE-HMD85 Hot Metal Detector is a robust sensor activated by the infra-red radiating from the hot product. Impervious to water or steam it is built to withstand the harshest of environments. The product is detected via a highly stable InGaAs Photodiode to ensure detection regardless of heavy water and steam and incorporates filtering that removes the visible spectrum to minimize sensitivity to extraneous light. The precise 0.5° x 25° lens ensures accurate detection of strip and accommodates bar bounce.
MSE-HMD85 Hot Metal Detector is the economical choice. Now there is no need to stock various Detectors for each location. Costly multiple inventory can be replaced by one Detector.
2. Rear Bar Display
The rear bar display allows the user to clearly establish the amount of received IR both from the background metalwork and the bar being detected and thereby establishing the correct trip level required. This display also allows the user to align the Detector from a low energy source such as a flashlight, which normally would be insufficient to switch the Detector. Adjustment of both the threshold and the response time is also clearly defined by this bar.
3. Air & Water Specifications
Air Pressure: 1 cu ft./min at 5 PSI for normal conditions
5 cu ft./min at 15 PSI for severe conditions
Water Pressure: 5 to 10 PSI, 40 PSI Maximum
Water Volume: Regulate between 0.2 - 0.3 liters/min.
Water Temp.:
For Ambient Temperature up to 70°C use ambient water below 20°C
For Ambient Temperature up to 80°C use water chilled up to 10°C
4. General Specification
Lens F.O.V. (Filed of View) | 0.5° x 25° Rectangular Slit |
Sensing Element | InGaAs Sensor |
Power Indication | Blue LED |
Function Indication | Top & Bottom Yellow LED's |
Remote Self-Check | Middle Yellow LED's |
Min/Max I.R. Threshold Settings | Adjustable from 270°C via Programming Switch |
Response Time | 1 ms to 250 ms, via Programming Switch |
Supply Voltage | Standard: 80 - 240 VAC, 50/60 or 24 VDC ± 10% |
Power Consumption | 5 W |
Operating Temperature | 1. -20°C to +50°C without Air Cooling 4. up to 80°C with Heat Shield |
Contact us
If You are interested in cooperation or need some more information, please contact us.
Moduloc System Engineering Co., Ltd. (Yantai) | |
Jerry Liu | |
Telephone: | 86-0535-2161086 |
Mobile Phone: | 150 9850 7080 |
Skype: | lxw-mse |
Website: | |
http://mse-system.en.china.cn |