Ultrasonic cavitation liposuction beauty equipment (very hot in Europ!!!)BS-05
USD $100 - $3,000 /Piece
Min.Order:1 Piece
Guangzhou Jimy Facial & Hair Beauty Products Co., Ltd.
Ultrasonic cavitation liposuction beauty equipment (very hot in Europ!!!)BS-05
1.Working Theory:
Vacuum and Ultrasonic Cavitation Slimming Beauty Equipment takes the strong ultrasonicheads to release 40,000Hz or 1 MHZ powerful ultrasonic, speedy vibrates fattiness cells, produces countless vacuum air pocket in and out of cells, mightily impacts the fatty cells, makes the cell membrane produce the inner cracking, so as to dissolve the triglyceride to be the glycerin and free fatty acid, then under the function of cavitations, to exhaust them out through the liver sausage circulation, at last, uses the Ultrasonic Locating plate to do skin tightening, gets the body slimming and beauty effect
1.2 Function
Tighten the flabby skin.
Increase the body’s metabolic rate; help the body excrete waste and moisture quickly.
Repair striate gravid arum.
Relax the muscles, lift the muscle cramps, and ease muscle pain and so on.
Lose weight.
Effectively cure the orange peel skin on buttock or thigh, solve the problem of the flabby abdominal skin after procreating or liposuction
1.3 Technical Advantages
Adopt the top ultrasonic liposuction technique in the world.
Suitable for all kinds of skin.
Comfortable, painless, woundless during the treatment.
Easy operation, easy study.
Non- exhaustion, low cost investment and quick high returns..
1.4 Features
Free operation, Non-anaesthetic.
No ruggedness.
No bleeding, tumidness and bruise.
No side effects, good effects, no rebounding phenomenon. Woundless, will not influence the normal working and living.
2.1 Touch screen display
2.2 Accessories Illustration
Vacuum+Blue led head (1Mhz): Negative pressure push the fat cells, accelerate the fat metabolism, promote the body lymph drainage, get the fat-sucking and body shaping effect with no-needle.
M50 US head(1Mhz): Strongly break down the fat cells.
M80 US head (40kHz): Strongly break the fat cells to pieces, and produce the inner exploding and melting.
4X Light-wave location plate(80Khz): Locate and tighten the skin, enhance the skin elasticity, accelerate to dissolve the Triglyceride, and make it exhause out of the body throu liver and sausage circulation.
2.3 INSTALLATION & WIRING
2.4 ACCESSORIES LIST
Description | Qty. |
Vacuum+Blue led head (1Mhz) | 1pc |
M50 US head(1Mhz) | 1 |
M80 US head (40kHz) | 1 |
4X Light-wave location plate(80Khz) | 4pcs |
Foot Pedal/ Power cord | 1pc each |
English manula | 1book |
3.1Working steps:
Special tips: 1. Check whether all the accessories are properly connected, clean and disinfect the equipment accessories
2. Power on the machine, and turn on the machine on the back. There shows the Chinese/English on the low-left part on the screen. Please choose the language you want.
3. Click the machine picture, and then it shows the operating interface.
Step ONE: Break the fat cells.
Spare part: M80 US head(40kHz)
Time: 20mins
Step Two:Crack the fat cells.
Spare part: M50 US head (40kHz)
Time: 10mins
Operation Ways:
a)Click the time,so the arrow will appear,then click the arrows on the two sides of “Start/ Pause” button to set up the time.
b)Click the pictures of “M50-Mode”, (screen will show the green “∨” signal), there is 10 different ultrasoni modes (P1-P10). The frequency is from slow level to fast level,so please choose the right mode according to the treatment demand. Then click the “M50-Intensity” button,and click the arrows on the two sides of “Start/ Pause” button to decrease and increase the intensity.(The original setting is from 5W/cm2 to 25 W/cm2,so can choose the right intensity according to the customers’ most comfortable feeling). After the above adjustment,click the“Start/ Pause” button,the signal will start to flash.Then use the M50 US head to work on the customer’s skin according to the tox-removing massage ways.
After the operation,click the “Start/ Pause” button to pause the work.Click the “M80-Mode” button,the signal under the M80-Mode Head picture will change into red “X”,so this spare part stops working.
Step Three:Vacuum and Remove fat
Spare part: Vacuum+Blue led head (1 MHz)
Time: 30mins
Operation Ways:
Click the time, so the arrow will appear, and then click the arrows on the two sides of“Start/ Pause” button to decrease and increase the time.
a) Vacuum Mode Adjustment
Click the “Vacuum-Mode” button, (The screen will show green ∨ signal). There is 6 different vacuum modes (P1-6) to choose according to the Air Inhaling and Deflating frequency from this machine. Then click the arrows on the two sides of “Start/ Pause” button to choose the right mode.(1-3 means the manual control mode,4-6 means the automatic mode. Please choose the right mode according to different treated part)
b) Vacuum Intensity Adjustment
Click “Vacuum Intensity” button firstly. The fixed data is from 10 to 100Kpa. Then click the arrows on the two sides of the “Start/ Pause” button to choose the right intensity.
c) Vacuum Inhaling Adjustment
Click “Vacuum Inhale-T” button to adjust the sucking time. The fixed inhaling time is 3.0S.(1-3 means the manual control mode, and the inhaling time can be adjusted according to the treatment demand;4-6 means the automatic mode, the Mode 4’s inhaling time is 8s,the Mode 5’s inhaling time is 13s,the Mode 6 is the continuous inhaling mode.) Please choose the right mode according to different treated part by clicking the arrows besides the “Start/ Pause” button).
d) Vacuum Deflating Adjustment
Click “Vacuum Deflate-T” button to adjust the sucking time. The fixed inhaling time is 3.0S.(1-3 means the manual control mode, and the inhaling time can be adjusted according to the treatment demand;4-6 means the automatic mode, the Mode 4’s inhaling time is 8s,the Mode 5’s inhaling time is 13s,the Mode 6 is the continuous inhaling mode.) Please choose the right mode according to different treated part by clicking the arrows besides the “Start/ Pause” button).
e) Ultrasonic Mode adjustment
Click “Supersonic Mode” button. There is 10 different working modes from this machine, the frequency is from slow level to fast level. Then click the arrows on the two sides of the “Start/ Pause” button to choose the right intensity.
f) Ultrasonic Intensity adjustment
Click “Supersonic Intensity” button to adjust the ultrasonic intensity,It can be from 0.5 W/cm2to 5.0 W/cm2. Then click the arrows on the two sides of the “Start/ Pause” button to choose the right intensity.
After adjusting all the functions, click the “Start/ Pause” button, the working signal will flash, so the machine will be in working status.
After the operation, click the “Start/ Pause” button to pause the work. Click the “M50-Mode” button, the signal under the Head picture will change into red X, so this spare part stops working.
l Step Four: Locating and tightening
Spare part:4X Light-wave location plate (80Khz)
Time: 10mins
3.2 Gesture suggestion
Shippment Way