2016 Hot Selling Full Automatic Chemistry Analyzer AJ-1269V
USD $1 - $2 /Unit
Min.Order:1 Unit
Anjue Medical Equipment Co., Ltd.
System Functions
-Analysis Method: end-point, kinetic, two-point, double-reagent, double-wavelength, multi-standard etc, open to various reagents
Sample/Reagents Handling
-Sample volume: 1-50µl, 0.5µl step
-Sample Dilution: automatic/Manual pre-dilution, with dilution ratio up to 1:100
-Reagent Position: 26 pcs (With refrigerated function, 2-8℃ )
-Reagent Volume: 180-600µl, 1µl step
Reaction System
- Reaction Cuvette: 60 pcs made of special material
- Optical Length of Cuvette: 6mm
- Reaction Volume: 150~400µl
-Reaction Time: 8-12 minutes
- Reaction Temperature: 37±0.1℃
Optical System
- Light Source: halogen-tungsten lamp
- Wavelength: 300-800nm, 8 wavelengths, precision ±2nm
- Absorbance Range: 0~3.0Abs
- Resolution: 0.001Abs
- Rear spectrophotometry
Calibration
-Calibration: linear/nonlinear multi-points calibration
-Re-test: retest the sample automatically when the result is out of the linearity range or the sample is not sufficient
Working Condition
- Power Supply: ~100-240V, 50/60Hz, ≤350W
- Temperature: 10-35℃
- Humidity: ≤90%, no dew
Operation System
- Windows XP or Windows 2000
Input and Output
- Input: RS-232 interface/computer
-Output: multi-format printout
Dynamic and Real-time display of running status
-Real-time online monitoring running status of sample tray, reagent tray cuvette
-Real-time online monitoring reagents residual volume
-Real-time online monitoring waste volume
Optimum calibration cuvette
-Automatic Cuvette blank testing
-Automatic wash selected cuvettes
-Real-time online monitoring running status of cuvette
Automatic dilute and re-test
-Automatic dilute and re-test when absorbance range is out of range
-Automatic dilute and re-test when linear limit is out of range
-Automatic dilute and re-test when linear range is out of range
-Two modes(no dilute and auto dilute)are available
-Freely set the auto dilute ratio and dilute water position
A real automatic biochemistry analyzer but only
-Small space: 54.8cmX42.2cmX38.3cm
-Easy to carry: weight ≤23kg
Opportunity to replace semi-auto biochemistry
analyzer
-Decrease the labor cost
-Independent mixing probe
-Reduce the reagent consumption: 300ul/test
-Efficiency speed: 200 tests/hour, less waiting time
-Easy to operate: Friendly and Intellective Software
-Accurate results: Avoid operative error/random error
-Good reputation for Clinic
Sample/Reagent Position
-18pcs sample position
-Reagent refrigerated function
-26pcs reagent position
Reaction Cuvettes
- 60 pcs reusable cuvettes
- Automatic blank testing for cuvette
-Colorimetry system in the pattern of light splitting behind cuvette
-Dismountable, easily replacement
Sample/Reagent/Mixing Probe
-Automatic liquid level detect
-Collision protection function
-Probe internal/external washing
-Clot detection function
- Independent mixing probe
7-Step Auto Cleaning System
-Automatic 7-step washing
-Hi-tech washing station to ensure accurate results
-With low water consumption: 1-2L/H