Model | S-50-5 | S-50-12 | S-50-15 | S-50-24 | S-50-36 | S-50-48 |
| DC voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Voltage tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated current | 10A | 4.2A | 3.4A | 2.1A | 1.4A | 1A |
Current range | 0~10A | 0~4.2A | 0~3.4A | 0~2.1A | 0~1.4A | 0~1A |
Rated power | 50W | 50.4W | 51W | 50.4W | 50.4W | 48W |
Ripple&noise | 100mvp-p | 120mvp-p | 120mvp-p | 120mvp-p | 150mvp-p | 150mvp-p |
DCvoltage ADJ.range | -9%~+10% | ±10% | ±10% | ±10% | ±10% | ±10% |
| Voltage range | 90~132VAC/180~264VAC(selected by switch), 255~373VDC |
Frequency | 47~63Hz |
AC current | 1.3A/115VAC, 0.65A/230VAC |
Efficiency | 76% | 79% | 79% | 80% | 81% | 81% |
Inrush current | cold start current 18A/115VAC, 36A/230VAC |
Leakage current | < 3.5mA/240VAC |
| Overload | above 115%~150% rated power |
protection type: part layer type current limit, auto-recovery after fault condition is removed |
Environment | Working temp,humidity | -10°C~+60°C, 20%~90%RH |
Storagetemp,humidity | -20°C~+85°C, 10%~95%RH non-condensing |
Withstand vibration | 10~500Hz, 2G 10min/1cycle, period for 60 minutes, each axes |
Safety | Withstand voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC |
| Isolated resistance | I/P-O/P,I/P-FG,O/P-FG: 100M ohms/500VDC |
Fitstandard | Safety standard | Fit UL1012 |
| EMC standard | meet EN55022, CLASS A |
Others | Dimension | 159*97*38mm (L*W*H) |
| Weight/packing | 0.5g/45pcs/ 23.5kg/0.041 m³/1.45CUFT |
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |