Model | | LPV-50-12 | LPV-50-24 | LPV-50-36 |
| DC voltage | 12V | 24V | 36V |
Voltage tolerance | ±1% | ±1% | ±1% |
Rated current | 4.2A | 2.1A | 1.4A |
Current range | 0~4.2A | 0~2.1A | 0~1.4A |
Rated power | 50.4W | 50.4W | 50.4W |
Ripple&noise | 100mvp-p | 150mvp-p | 180mvp-p |
| Voltage range | 170~264VAC,235~373VDC |
Frequency | 47~63HZ |
AC current | 0.65A/230VAC |
Efficiency | 82% | 84% | 85% |
Inrush current | Cold start current 35A/230VAC |
Leakage current | <1mA/240VAC |
| | Rated output power 115%~150%start over load protection |
Protection type:hiccup mode,auto-recovery after fault condition is removed |
| 15.6~17.8V | 30.6~33.2V | 42.6~44.2V |
Protection type:hiccup mode,auto-recovery after fault condition is removed |
| Shell temp≥85°C,start over temperature protection |
Protection type:hiccup mode,auto-recovery after fault condition is removed |
| Working temp,humidity | -10°C~+60°C,20%~90%RH |
Storage temp.humidity | -20°C~+85°C,10%~95%RH non condensing |
Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60minutes,each axes |
| Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC |
| Safety standard | Fit UL1012,IP67 protect level |
tandard | EMC standard | Fit EN55022,CLASSA |
| Dimension | 190*49*34mm (L*W*H) |
Weight/packing | 0.53kg/30pcs/17kg/0.025 m⊃3;/0.87CUFT |
| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. |
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. |
3. Tolerance : includes set up tolerance, line regulation and load regulation. |