Model Specification | S-15-5 | S-15-12 | S-15-15 | S-15-24 |
DC output voltage | 5V | 12V | 15V | 24V |
Output voltage error(Note,2) | ±2% | ±1% | ±1% | ±1% |
Rated output current | 3A | 1.3A | 1A | 0.7A |
Output current rage | 0-3A | 0-1.3A | 0-1A | 0-0.7A |
Wave and noise(Note ,3) | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlet stability(Note ,4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stablity (Note ,5) | ±1% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 15W | 15W | 15W | 15W |
Efficiency | 70% | 76% | 78% | 78% |
Adjustable range for DC voltage | +10,-5% | +10% | +10% | +10% |
AC input voltage range | 85-132VAC/170-264VACSelected by switch47-63Hz,240-370VDC |
Input current | 0.5A/115V 0.25A/230A |
AC INnrush current | Cold-start current15A/115V 30A/230V |
Leakage current | <0.5mA/240VAC |
Overload proctection | 105%-150%Type:Foldback:current limiting reset:auto recovery |
Over-voltage protection | ………… |
High-temperature protection | ………… |
Temperature coefficient | ±0.03%/°C(0-50°C) |
Setup rise hold up time | 200ms,100ms,30ms |
Vibration | 10-500HZ,2G 10min,/1cycle,Period for60min,Each axes |
Withstand voltage | Input and output internal,1.5KVAC,Input and enclosure,1.5KVAC,Output and enclosure0.5KVAC |
Isolation resistance | Input and output internal:Input and enclosure,Output and enclosure,500VDC/100MΩ |
Working temperature and humidity | -10°C~+60°C(Refer to output derating curve),20%~90%RH |
Store temperature and humidity | -20°C~+85°C.10%~95%RH |
Overall dimension | 99*97*35mm |
Weight | 0.3Kgs |
Safety standards | Meet UL 1012 requirement(Not apply for the mark) |
EMC standards | Meet FCC part15J Conduction classB |
| 1.The testing condition for the paramenter above is ,230VAC input,rated load,25°C70% RH.Humidity. 2.Error.include the setting error,line stability and load stability.(Note:5). 3.Wave test:adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting. 4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. 5.Load stability test:the load is from 0% to 100% |