Switch Power Supply

Switch Power Supply

USD $0.1 - $10 /Piece

Min.Order:1000 Pieces

Supply Ability:
1000000 Piece / Pieces per Month
Port:
china port
Payment Terms:
T/T L/C D/P D/A Credit Card

Quick Details View All >

Place of Origin:
Zhejiang, China
Brand Name:
SENTAI
Model Number:
DR-120
Output Power:
101 - 200W
Output Type:
Other, DC
Input Voltage:
Other, 230V

Zhejiang Sentai Electrical Apparatus Factory

Credit Member 4 years
Business Type: Manufacturer
Wenzhou Zhejiang China
Main Products: Mini Circuit Breaker ,Moulded Case Circuit Breaker ,Air Circuit Breaker ,Energy Meter ,Multimeter

Product Details

Specifications

1.High efficiency and low operation temperature
2.Soft-start current can reduce the AC input impact effecticly

Model
DR-120-12DR-120-24DR-120-48
Specification
DC output voltage12V24V48V
Output voltage range(Note:2)±2%±1%±1%
Rated outpru current10A5A2.5A
Output current range0-10A0-5A0-2.5A
Wave and noise(Note:3)80mVp-p80mVp-p100mVp-p
Inlet stability(Note:4)±0.5%±0.5%±0.5%
Load stability(Note:5)±1%±1%±1%
DC output power120W120W120W
Efficiency80%84%85%
Adjustable range
for DC voltage
10.8~13.2V21.6~26.4V43.2~52.8V
AC input voltage range88~132VAC 47~63Hz;248~370DC
Input current3.3A/115V 2A/230V
AC Inrush currentCold-start current 30A/115V 60A/230V
Leakage current<3.5mA/240VAC
Overload proctection105%~150% Type:pulsing hiccup
shutdown Reset:auto recovery
Over-voltage protection13.8~16.2V27.6~32.4V58~62V
High-temperature protection85±5(TSW1)90±5(TSW1)90±5(TSW1)
Temperature coefficient±0.03%/(0~50)
Setup,rise,hold up time500ms,70ms,50ms/230V
Vibraton10~500Hz,2G 10min,/1cycle,period for 60min,Each axes 
Withsatnd voltageInput and output internal:1.5KvAC,input and  enclosure:1.5Kv
AC,output and enclosure:0.5KvAC
Isolation resistanceInput and output internal,input and enclosure,output and enclosure:500VDC/100M
Working termperature
and humidity
-10~+60(Refer to output derating vurve),20%~90%RH
Store temperature and humidity-20 +85,10%~95%RH
Overall dimension78*93*56mm
Weight 0.27Kgs
Safety standardsMeet UL 1012R requirement
(Not apply for the mark)
EMC standardsMeet FCC PART15 J Conduction class B
Note:1.The testing condition for the paramenter above is:230VAC input,rated load,2570% RH,Temperature.
2.Error.include the setting error,line stability and load stability.(Note:5)
3.Wave test:adopting"A12"double wire for 20MHz and 0.1UF&47UF capacitor short-circuit for interrupting
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. 
5.Load stability test:The load is from 0% to 100%.

Contact Supplier

Mr. Nicolas Shu Sales Manager Chat Now
Telephone
86-577-61728658
Mobile
86-13587450310
Fax
86-577-62721271
Address
Liushi Sentai Industrial Park, Yueqing City Wenzhou,Zhejiang

You May Like