Switch Power Supply
USD $0.1 - $10 /Piece
Min.Order:1000 Pieces
Zhejiang Sentai Electrical Apparatus Factory
| DR-60-5 | DR-60-12 | DR-60-15 | DR-60-24 | |
Specification | |||||
DC output voltage | 5V | 12V | 15V | 24V | |
Output voltage range(Note:2) | ±2% | ±1% | ±1% | ±1% | |
Rated outpru current | 6.5A | 4.5A | 4A | 2.5A | |
Output current range | 0-6.5A | 0-4.5A | 0-4A | 0-2.5A | |
Wave and noise(Note:3) | 100mVp-p | 200mVp-p | 240mVp-p | 480mVp-p | |
Inlet stability(Note:4) | ±1% | ±1% | ±1% | ±1% | |
Load stability(Note:5) | ±1% | ±1% | ±1% | ±1% | |
DC output power | 32.5W | 54W | 60W | 60W | |
Efficiency | 72% | 77% | 77% | 80% | |
Adjustable range for DC voltage | 4.75~5.5V | 10.8~13.2V | 13.5~16.5V | 21.6~26.4 | |
AC input voltage range | 85~264VAC 47~63Hz;120~370DC | ||||
Input current | 1.5A/115V 0.75A/230V | ||||
AC Inrush current | Cold-start current 30A/115V 60A/230V | ||||
Leakage current | <1mA/240VAC | ||||
Overload proctection | 105%~150% Type:pulsing hiccup shutdown Reset:auto recovery | ||||
Over-voltage protection | 105%-150% type:pulsing hiccup shutdown reset:auto recovery | ||||
High-temperature protection | .................... | ||||
Temperature coefficient | ±0.03%/(0~50) | ||||
Setup,rise,hold up time | 800ms,60ms,50ms/230V | ||||
Vibraton | 10~500Hz,2G 10min,/1cycle,period for 60min, Each axes | ||||
Withsatnd voltage | Input and output internal:1.5KvAC,input and enclosure:1.5Kv AC,output and enclosure:0.5KvAC | ||||
Isolation resistance | Input and output internal,input and enclosure,output and enclosure:500VDC/100M | ||||
Working termperature and humidity | -10~+60(Refer to output derating vurve), 20%~90%RH | ||||
Store temperature and humidity | -20 +85,10%~95%RH | ||||
Overall dimension | 78*93*56mm | ||||
Weight | 0.27Kgs | ||||
Safety standards | Meet UL 1012R requirement(Not apply for the mark) | ||||
EMC standards | Meet FCC PART15 J Conduction class B | ||||
Note:1.The testing condition for the paramenter above is:230VAC input,rated load,2570% RH,Temperature. | |||||
2.Error.include the setting error,line stability and load stability.(Note:5) | |||||
3.Wave test:adopting"A12"double wire for 20MHz and 0.1UF&47UF capacitor short-circuit for interrupting | |||||
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. | |||||
5.Load stability test:The load is from 0% to 100%. |