Switch Power Supply
USD $0.1 - $10 /Piece
Min.Order:1000 Pieces
Zhejiang Sentai Electrical Apparatus Factory
Model | DR-240-24 | DR-240-48 |
Specification | ||
DC output voltage | 24V | 48V |
Output voltage range(Note:2) | ±1% | ±1% |
Rated outpru current | 10A | 5A |
Output current range | 0-10A | 0-5A |
Wave and noise(Note:3) | 80mVp-p | 150mVp-p |
Inlet stability(Note:4) | ±0.5% | ±0.5% |
Load stability(Note:5) | ±1% | ±1% |
DC output power | 240W | 240W |
Efficiency | 84% | 85% |
Adjustable range for DC voltage | 21.6~26.4V | 43.2~52.8V |
AC input voltage range | 88~264VAC 47~63Hz;120~370DC | |
Input current | 3.5A/115V 1.8A/230V | |
AC Inrush current | Cold-start current 30A/115V 60A/230V | |
Leakage current | <3.5mA/240VAC | |
Overload proctection | 105%~150% Type:pulsing hiccup shutdown Reset:auto recovery | |
Over-voltage protection | 30~34V | 54~60V |
High-temperature protection | 100±5(TSW1) | |
Temperature coefficient | ±0.03%/(0~50) | |
Setup,rise,hold up time | 800ms,40ms,20ms/230VAC 800ms,40ms,20ms/115VAC | |
Vibraton | 10~500Hz,2G 10min,/1cycle,period for 60min,Each axes | |
Withsatnd voltage | Input and output internal:1.5KvAC,input and enclosure:1.5Kv AC,output and enclosure:0.5KvAC | |
Isolation resistance | Input and output internal,input and enclosure,output and enclosure:500VDC/100M | |
Working termperature and humidity | -10~+60(Refer to output derating vurve),20%~90%RH | |
Store temperature and humidity | -20 +85,10%~95%RH | |
Overall dimension | 125.5*125.2*100mm | |
Weight | 1.2Kgs 20PCS/14.4Kg/1.2CUFT | |
Safety standards | Meet UL 1012R requirement (Not apply for the mark) | |
EMC standards | Meet FCC PART15 J Conduction class B | |
Note:1.The testing condition for the paramenter above is:230VAC input,rated load,2570% RH,Temperature. | ||
2.Error.include the setting error,line stability and load stability.(Note:5) | ||
3.Wave test:adopting"A12"double wire for 20MHz and 0.1UF&47UF capacitor short-circuit for interrupting | ||
4.Inlet voltage stability test:when is over load,the lowest voltage of inlet is up to the highest voltage. | ||
5.Load stability test:The load is from 0% to 100%. |