Switching power supply
USD $5.8 - $6 /Piece
Min.Order:1000 Pieces
Zhejiang Sentai Electrical Apparatus Factory
1.Low price and high reliability
2.105°c output capacitor
3.AC input power suitable for the world
4.High efficiency and low operation temperature
5.Soft-start current can reduce the AC input impact effectively
6.With short-circuit and overload protection
7.Compact size, light weight
8.100% full-load burning test
9.Installed with EMI filter, minimum wave
Model Specification | S-50-5 | S-50-12 | S-50-15 | S-50-24 | |
DC output voltage | 5V | 12V | 15V | 24V | |
Output voltage error (Note2) | ±2% | ±1% | ±1% | ±1% | |
Rated output current | 10A | 4.2A | 3.4A | 2.1A | |
Output current rage | 0-10A | 0-4.2A | 0-3.4A | 0-2.1A | |
Wave and noise(Note3) | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
Inlet stability(Note4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load stability(Note5) | ±1% | ±0.5% | ±0.5% | ±0.5% | |
DC output power | 50W | 50.4W | 50.4W | 50.4W | |
Efficiency | 71% | 78% | 78% | 82% | |
Adjustable range for DC voltage | ±10,-5% | ±10% | ±10% | ±10% | |
AC input voltage range | 85~132VAC/170~264VACselected by switch | ||||
Input current | 1.3A/115V 0.65A/230V | ||||
AC impulse current | Cold-start current 18A/115V 36A/230V | ||||
Leakage current | <0.5mA/240VAC | ||||
Overload protection | 105%~150%Type:TOLDBACK Reset: auto recovery | ||||
Over-voltage protection | …… | ||||
High-temperature protection | …… | ||||
Temperature coefficient | ±0.03%°c(0~50°c) | ||||
Setup rise hold up time | 200ms,100ms,30ms | ||||
Vibration | 10~500Hz,2G 10min./1cycle,Period for 60min,Each axes | ||||
Withstand voltage | Input and output interval:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC | ||||
Isolation resistance | Input and output interval,Input and enclosure,Output and enclosure:0500VAC/100M Ohms | ||||
Working temperature and humidity | -10°c~+60°c,20%~90%RH | ||||
Store temperature and humidity | -20°c~+85°c,10%~95RH | ||||
Overall dimension | 159*97*38mm | ||||
Weight | 0.5Kgs | ||||
Safety standards | Meet UL1012 | ||||
EMC standards | …… | ||||
Note:1.The testing condition for the parameter above is:230VAC input, rated load,25°c 70%Rh,Humidity |