Feature:Volumetric rotary piston principle of measurement; LXH(Y)-15~20 is no location limitation for installation. Accuracy is not to be affected
wherever installed at a horizontal, vertical or inclined pipeline; Register is sealed with a special liquid to keep a clear reading in long term service; Mechanism use of high-quality material to ensure a stable characteristic; Accurate measurement with conformity to ISO 4064 :2005;R160 LXHY-15~20 Pulse output:0.5L/pulse .
Working Condition:
Water temperature:<50℃ Water pressure:≤1.6Mpa(16bar)
Maximum Permissible Error
in the lower zone from Q1 inclusive up to but excluding Q2 is ±5%.
in the upper zone from Q2 inclusive up to and including Q4 is ±2%
Main Technical Specifications