Measuring the volume of cold potable water passing through the pipeline
Brand Name
MIDAS
Packaging
Carton, pallet and as per customer's requirement.
Application: Measuring the total volume of portable water passing through the pipeline. It can be equipped with pulse output assembly (reed switch).
Feature: Compact design, light weight, magnet transmission register which could be rotation in 360°for convenient reading. Note: 1.The water mwter complies with the standard of <>(ISO4064-1~3:2005,IDT) 2. For hot water up to 90℃ is available on request.
Metrological requirements: Temperature class:for cold water:T30 , for hot water:T30/90 Water pressure class:MAP10 or MAP16 on request Pressure-loss class:Δp63 Sensitivity to the irregularity in the upstream velocity fields class:U10 Sensitivity to the irregularity in the downstream velocity fields class:D5
Maximum permissible error: 1)In the lower zone(Q1≤Q<Q2)±5% 2)In the upper zone(Q2≤Q≤Q4): for water temperature up to 30℃ ±2% from 30℃ up to 90℃ ±3%