Hawker Genesis Ainoshawk Battery NP65-12 Lead Acid Energy Storage Industrial 12V65AH/Maintenance Free
CNY 744 - 851 /Bag
Min.Order:1 Bag
Beijing Lusheng Power Equipment Co., Ltd
VMF-BATTERY deep cycle lead-acid battery DC60-12 German source 12V60AH battery screen
German source battery VMF deep cycle battery DC210-12 machine room continuous power supply
Lusheng RUZET battery France 12LPG90/12V90ah maintenance free communication room
RUZET France Lusheng Battery 12LPG33 12V33Ah Communication Machine Room Elevator
Lusheng France RUZET battery 12LPA180 emergency battery screen
Lusheng RUZET French battery 12LPA7 industrial battery 12V7AH communication room
Hawk Genesis Battery
Battery manufacturing standards:
National standard: GB/T 19638.2 "Fixed valve regulated sealed lead-acid batteries"
Communication industry standard: YD/T 799-2010 "Technical Requirements and Requirements for Valve Regulated Sealed Lead Acid Batteries for Communication"
Testing Methods
Power industry standard: DL/T 637-1997 "Technical Conditions for Ordering Valve Regulated Sealed Lead Acid Batteries"
Two main performance indicators:
1. Working environment: Normal use under ambient temperature conditions of -15 ℃~+45 ℃.
2 Structure: The terminals are connected by bolts and nuts, and the voltage drop between the batteries is Δ U ≤ 10mV.
3 Appearance; No deformation, cracks, or oil stains.
4. Airtightness: The battery can withstand a positive or negative pressure of 50Kpa without breaking or opening the adhesive, and the shell remains intact after the pressure is released
The remaining deformation.
5 Capacity: The capacity of 10h rate shall not be less than 0.95C10, and shall reach C10 for the third time.
6 high current discharge: discharge at 30I10 (A) for 3 minutes, the pole should not melt and there should be no abnormalities in appearance.
7. Impact discharge capability: meets the requirements of Article 4.13 of DL/T 637-1997 standard.
8. Charge holding capacity: After 90 days of standing, its capacity shall not be less than 80%.
9. Sealing reaction efficiency: not less than 98%.
10 Anti acid mist ability: No acid mist escapes during normal operation.
11 Safety valve requirements: open valve pressure 10Kpa~49Kpa, close valve pressure 1Kpa~10Kpa.
Design life ≥ 8 years, service life ≥ 5 years.
Three application scopes:
1. Telecommunications department, microwave relay station, broadcasting and television network
2. Power plants and substations
3. UPS, uninterruptible power supply, backup power supply
4. Control system and telemetry equipment
5. Solar and wind energy storage systems