PMA240-1050B-02 Switching power supply safety power supply
Negotiable /Bag
Min.Order:1 Bag
Product Overview:
The main unit used to control any other expansion unit can also work independently
As the main unit: controlling more complex systems, providing protection for large machinery with multiple sensors
As an independent: control small machinery connected to up to 4 safety devices, namely 1 safety light curtain, 1 emergency stop, 1 magnetic sensor, and 1 two handed switch
Safety level: PL e
Safe input: 8 digital inputs
Safety level (SIL/PL): SIL 3- SILCL 3- PL e - Cat four
Working temperature (° C): -10 to 55
Signal display: LED indicates working status and fault diagnosis. LED indications: input, OSSD output, reset request, and status output conditions
Safe output type: 2 pairs or 4 single (at 400 mA, 24 VDC) self control, with short circuit, overload, and parity reverse protection functions
Connection: detachable terminal block, screw contacts
MTTFD (ISO 13849-1) Age: 30 one hundred
PFHD (IEC 61508): 1,34E-08
Safe output quantity: 2 pairs or 4 units (400 mA)
Programmable signal output: 4 PNP (100 mA)
Test output: 4
Storage temperature (° C): -20+ eighty-five
MSC connector: None
Connected to MSC bus: Yes
Start/restart output and EDM: 4
MCM Housing: Yes
USB input: Yes
Packaging dimensions W x H x L (mm): 36 x 127 x 113
Power supply (VDC): 24 ± 20%
Size HxWxD (mm): 108 x 22,5 x 114,5
Protection level: IP 20 for enclosure - IP 2X for wiring board
Tightening method: Guide rail fastening, in accordance with EN 50022-35 standard
Gross weight (g): 206,8
Contact information: 15359293870
WhatsApp:+86 15359293870
Contact person: KELLY
Email: geabbdcs@gmail.com 386353502@qq.com
Official website:
Bus data interface
*9-pin Sub_ D-jack connector, pin definition in accordance with Profibus DP protocol specifications
*Supports Profibus DP bus standard
*Signal delay (electrical port): ≤ 4Bit
*Communication speed: 9.6Kbps, 19.2 Kbps, 45.45Kbps, 93.75Kbps, 187.5Kbps, 500Kbps, 1.5Mbps, 3Mbps, 6Mbps, 12Mbps
*Equipped with 4000V lightning protection, 1.5A overcurrent protection, and 600W surge protection functions
*Terminal resistance: This device does not come with a terminal resistance, please connect it externally as needed
Power supply and protection
*Power supply: Dual power redundant input, DC (12-36V), typical DC24V, power consumption less than 4W, with reverse protection function, industrial terminal interface
*Relay alarm output: Bus data interface fault alarm output, contact capacity: DC48V/1 A, industrial terminal interface
mechanical properties
*External dimensions: (136x106x54) mm
*Shell: IP30 protection level, corrugated aluminum reinforced casing
*Installation method: 35mm guide rail installation
*Net weight: 800g
work environment
*Working temperature: -10 ℃~70 ℃, optional wide temperature product (-40~85 ℃)
*Storage temperature: -40 ℃~85 ℃
*Relative humidity: ≤ 90% (non condensing)