3350-MBP communication interface
Negotiable /Bag
Min.Order:1 Bag
Suzhou Xunpeng XP2001 I/O Module
Basic Performance of XP2001 Single Channel Data Acquisition Module
XP2001 universal input, input signals: thermocouple, thermal resistance, DC current/voltage input, can be selected through parameter settings.
XP2001A is fixed as a potentiometer input.
The standard configuration includes feeding and communication.
Input, communication, output, feeding, and module power supply are isolated from each other.
10VDC to 30VDC power supply, with a power consumption of less than 4.8W.
XP2001 Signal Acquisition Module. jpg
Selection Table for XP2001 Single Channel Data Acquisition Module
Signal acquisition module, data acquisition module, I/O module, digital I/O module, remote I/O module, analog input module, Analog I/O module, input/output module, RS485 acquisition module, switch value acquisition module, temperature acquisition module, analog output module, switch value output module
Contact information: 15359293870
WhatsApp:+86 15359293870
Contact person: KELLY
Email: geabbdcs@gmail.com 386353502@qq.com
Official website:
The scale is one tenth of a degree.
This module has 16 24 VDC digital outputs, PNP type, with a maximum current of 0.5 A per channel, typically used for heating and/or cooling.
Any available output can also be used to control the machine cycle.
All outputs have current cycling circuits for sensing loads, and have short circuit, overload, and overheat protection.
There is also a 24 VDC NPN digital input to measure the period of the applied signal.
The maximum input frequency is 1 kHz.
This module is installed on R-BUS (x) and receives power from it.
TBUS DIN rail for expansion modules and bus couplers
Rated control circuit power voltage US: 18 V DC 30 V DC (including all tolerances, including residual voltage)
Rated control circuit power voltage US: 24 V DC (A1/A2)
Rated control power supply current IS: typical value 110 mA
Limit continuous current: maximum 6 A (for loop current paths A1/A1 and A2/A2)
Delay time: typical value of 20 ms (depending on load, in case of voltage drop of US)
Protection circuit: Yes, within the operating voltage limit range
Status display: 3x green LED, 1x red LED
Input Description: Number, HTL type
Input quantity: 10 (dual channel, up to SIL 3)
20 (single channel, up to SIL 2)
Input voltage range, "0" signal: 0 V DC 5 V DC (for safe shutdown)
Input voltage range, "1" signal: 11 V DC 30 V DC
Cable length: maximum 2000 m
Status display: 20 x green LED (1 LED per input)
Power consumption: typical value 4 mA
Number of outputs: 4 (safe semiconductor output, up to Cat. 4 (according to EN ISO 13849-1)
2 (negative switching output)
Precautions for protecting the circuit: Yes, within the operating voltage limit range
Short circuit protection: Yes
Output voltage:<5 V (low state)
Leakage current: maximum 2 mA
Maximum capacitive load: maximum 1 µ F (electronic components)
Limit continuous current: 2 A (per channel, see derating)