PDP800
Negotiable /Bag
Min.Order:1 Bag
Product Overview:
The main unit used to control any other expansion unit can also work independently
As the main unit: controlling more complex systems, providing protection for large machinery with multiple sensors
As an independent: control small machinery connected to up to 4 safety devices, namely 1 safety light curtain, 1 emergency stop, 1 magnetic sensor, and 1 two handed switch
Safety level: PL e
Safe input: 8 digital inputs
Safety level (SIL/PL): SIL 3- SILCL 3- PL e - Cat four
Working temperature (° C): -10 to 55
Signal display: LED indicates working status and fault diagnosis. LED indications: input, OSSD output, reset request, and status output conditions
Safe output type: 2 pairs or 4 single (at 400 mA, 24 VDC) self control, with short circuit, overload, and parity reverse protection functions
Connection: detachable terminal block, screw contacts
MTTFD (ISO 13849-1) Age: 30 one hundred
PFHD (IEC 61508): 1,34E-08
Safe output quantity: 2 pairs or 4 units (400 mA)
Programmable signal output: 4 PNP (100 mA)
Test output: 4
Storage temperature (° C): -20+ eighty-five
MSC connector: None
Connected to MSC bus: Yes
Start/restart output and EDM: 4
MCM Housing: Yes
USB input: Yes
Packaging dimensions W x H x L (mm): 36 x 127 x 113
Power supply (VDC): 24 ± 20%
Size HxWxD (mm): 108 x 22,5 x 114,5
Protection level: IP 20 for enclosure - IP 2X for wiring board
Tightening method: Guide rail fastening, in accordance with EN 50022-35 standard
Gross weight (g): 206,8
Contact information: 15359293870
WhatsApp:+86 15359293870
Contact person: KELLY
Email: geabbdcs@gmail.com 386353502@qq.com
Official website:
TBUS DIN rail for expansion modules and bus couplers
Rated control circuit power voltage US: 18 V DC 30 V DC (including all tolerances, including residual voltage)
Rated control circuit power voltage US: 24 V DC (A1/A2)
Rated control power supply current IS: typical value 110 mA
Limit continuous current: maximum 6 A (for loop current paths A1/A1 and A2/A2)
Delay time: typical value of 20 ms (depending on load, in case of voltage drop of US)
Protection circuit: Yes, within the operating voltage limit range
Status display: 3x green LED, 1x red LED
Input Description: Number, HTL type
Input quantity: 10 (dual channel, up to SIL 3)
20 (single channel, up to SIL 2)
Input voltage range, "0" signal: 0 V DC 5 V DC (for safe shutdown)
Input voltage range, "1" signal: 11 V DC 30 V DC
Cable length: maximum 2000 m
Status display: 20 x green LED (1 LED per input)
Power consumption: typical value 4 mA
Number of outputs: 4 (safe semiconductor output, up to Cat. 4 (according to EN ISO 13849-1)
2 (negative switching output)
Precautions for protecting the circuit: Yes, within the operating voltage limit range
Short circuit protection: Yes
Output voltage:<5 V (low state)
Leakage current: maximum 2 mA
Maximum capacitive load: maximum 1 µ F (electronic components)
Limit continuous current: 2 A (per channel, see derating)