Mfr. #: HK4101F-DC12V-SHG
Safety Standard: C-UL CQC TUV
Contact Specification:
Contaact Gap: 0.3mm Minimum
Contact Resistance:
Maximum 100mΩ at initial value. Test Current: 1A, Open Circuit Test Voltage: 6VDC. By using Voltage Drop Metho
Contact Capacity:
3 Amps at 250VAC Cosφ=1. 3 Amps at 30V
Coil Specification at
20 °C:
Rated Voltage: 12VDC.
Nominal Current: 12.5/16.7/30
Rated Power
Consumption: 0.15W/0.2W0.36W
Coil Resistance: 960/720/400
Pull In Voltage:
≦ (Contact operating voltage when voltage is gradually applied. It is 80%
of the Rated Voltage) V DC
Drop Out Voltage: ≧ (Contact breaking voltage when rated voltage is gradually reduced. It is
10% of the Rated Voltage) VDC
Max. Allowable
Voltage:
(130% of the Rated Voltage) V DC
Operate Time: 6 milliseconds Maximum when rated Voltage is applied.
Release Time: 4 milliseconds Maximum when rated Voltage is suddenly cut off.
Coil Temperature
Rise: 40℃ Maximum. Maximum Allowable Voltage is applied to Coil while no load should be applied
to Contacts, then the temperature should be measured when the value is
stabilized. Environment temperature should not be included in.
Electrical
Characteristics:
Life Expectancy:
Electrical Life: 100,000 operations Minimum at 3A/250VAC Cosφ=1. 100,000 operations Minimum at3A/30VDC
Rated Voltage is applied.
Mechanical life: 10,000,000 operations Minimum at No Load condition.
Maximum
Operating
Frequency: Electrical: 30 operations/minute. Mechanical: 300 operations/minute.
Dielectric Strength:
Between
Contacts: 500VAC at Test Frequency 50/60 Hz, Leakage Current: 1mA for 1 minute.
Between Coil &
Contact: 1,000VAC at Test Frequency 50/60 Hz, Leakage Current: 1mA for 1 minute.
Insulation
Resistance: ≧100 MΩ Minimum. A Voltage of 500VDC should be applied after which measurement shall be
made.
Vibration:
Endurance I: The Coil shall be maintained under not energized condition, double amplitude
1.5 mm, the entire frequency range changes from 10 to 55 Hz then returns to
10 Hz shall be made in 1 minute. This motion shall be applied for a period of
2 hours in each of 3 mutually perpendicular axis (a total of 6 hours) There
should not be any deformations in construction and in appearance, while the
Electrical Specifications should be fulfilled after the test.
Endurance II
(Error
Operation): The Coil shall be maintained under energized condition, double amplitude 1.5
mm, the entire frequency range changes from 10 to 55 Hz then returns to 10
Hz shall be made in 1 minute. This motion shall be applied for a period of 5
minutes in 3 mutually perpendicular axis. Malfunction is not allowed during
the test (contact breaking time should be less than 1 millisecond) In addition,
there should not be any deformations in construction and in appearance while
the Electrical Specifications should be fulfilled after the test.
Shock:
Endurance I:
Peak Acceleration: 1000m
The Coil shall be maintained under not energized condition, 5 successive
shocks shall be applied in 3 mutually perpendicular axis. There should not
be any deformations in construction and in appearance while the Electrical
Specifications should be fulfilled after the test.
Endurance II
(Error
Operation): Peak Acceleration: 100m/s²
The Coil should be maintained under energized condition, 2 successive
shocks shall be applied in 3 mutually perpendicular axis. Malfunction is not
allowed during the test (contact breaking time should be less than 1
millisecond) In addition, there should not be any deformations in construction
and in appearance while the Electrical Specifications should be fulfilled after
the test.
Environmental
Characteristics:
Temperature Range:
Operating
Temperature
Range:
Operating temperature range is the range of ambient temperature of which the
Relay can be operated continuously within operative voltage range of coil (no
condensation of water drops under low temperature condition)
Storage
Temperature
Range: Storage temperature range is the range of ambient temperature of which the
Relay can be stored without damages (no condensation of water drops under
low temperature condition). Conditions are as specified elsewhere in these
specifications
Humidity Range: 35~85% RH.
Cold Resistance:
Cold
Resistance in
Use: Relay should be kept in temperature chamber at -30 ± 2°C for two hours that
no current or voltage shall be supplied to Relay. Such condition shall be
maintained while the rated voltage is supplied to Relay, then the Relay shall
operate normally. (No condensation of water drops under low temperature
condition)
Storage Cold
Resistance: Relay should be kept in temperature chamber at -40 ± 2°C for 72 hours. Then the Relays shall be maintained at standard atmospheric condition for 1
to 2 hours after which measurement shall be made. Construction, Relay
operation, Insulation Resistance and Dielectric Strength shall satisfy the
specification requirements. (No condensation of water drops under low
temperature condition)
Heat Resistance:
Heat
Resistance in
Use: Relay should be kept in temperature chamber at 70 ± 2°C for two hours that
rated Voltage should be supplied to Coil while rated Current should be
supplied to Contacts. Such condition shall be maintained while the rated
voltage is supplied to Relay, then Relay shall operate normally.
Storage Heat
Resistance: Relay should be kept in temperature chamber at 70 ± 2°C for 16 hours. Then
the Relays shall be maintained at standard atmospheric condition for 1 to 2
hours after which measurement shall be made. Construction, Relay
operation, Insulation Resistance and Dielectric Strength shall satisfy the
specification requirements.
Moisture
Resistance: Relay should be kept in temperature chamber at 40 ± 2°C (90~95% RH) for 48
hours. Then the Relays shall be maintained at standard atmospheric
condition for 1 to 2 hours after which measurement shall be made. Construction, Relay operation, Insulation Resistance, Dielectric Strength shall
satisfy the specification requirements.
Terminal Strength: A load of 300g should be applied to the Terminal for one minute in horizontal
direction. There should not be any looseness or bending of Terminals.
Soldering Dip Test: The front 3 mm of Terminal should be immersed for 3 ± 0.5 seconds at 230 ±
5°C. Soldered area must be minimum 90% of the soldering surface.
Soldering Heat Resista
Approx.10gnce: When the Terminal are immersed into soldering bath at 350 °C for 3 seconds,
the Relay shall satisfy all electrical and mechanical specifications and must
not have excessive change in outside appearance.
Weight: Approx.3.5g
Sample Test Method: GB2828-2000 Level – General II, AQL 0.4
Factory Pack Quantity: 25
Price: 0.4-0.5