Vacuum blade pet food extruder
30000 - 35000 /Piece
Min.Order:0 Piece
Zhucheng tianrun industry & trade co., ltd
Vacuum blade enema machine
VACUUM VANE ENEMA MACHINE
Construction: This machine consists of a rack, variable frequency control system, vacuum control system, vane pump, electrical box, hopper, etc. Vane pumps are mainly composed of pump shafts, impellers, blades, and cams, and their main purpose is to control discharge
Product Introduction:
1. All the plates used are made of 304 stainless steel material, which is sturdy and durable, and has a longer service life;
2. The filling process is completed in a vacuum state, effectively preventing fat oxidation, avoiding protein hydrolysis, reducing bacterial survival, and ensuring the product's shelf life, bright color, and mellow taste;
3. It can be used as a filling equipment and can also lift and transport materials over long distances;
4. Equipped with a frequency converter, it can achieve frequency conversion and speed regulation function;
5. The blade type filling machine has better adaptability to materials: extrusion or filling of mixed materials containing shredded meat, meat pieces, vegetables, and broken bones. Its working principle is to use vane pump filling.
Equipped with a cutting machine, it can directly cut extruded food, as well as freeze-dried and dried food. Smooth pet food production line, time-saving, labor-saving, and labor-saving.
Advantages: The material is pushed out of the filling tube by rotating the blades in a vacuum state, completing the filling and realizing material transmission. There is no cross pressure action during the entire transmission process, so the raw material will not be damaged during the transportation process, achieving complete transportation.
Usage: pet snack extrusion, sandwich snack extrusion, wet grain processing, pet food filling, freeze-dried food extrusion, dried food extrusion, dog food processing.
Vacuum blade enema machine
VACUUM VANE ENEMA MACHINE
Parameter table:
Name
Speed (r/min)
power
(kw)
voltage
(v)
Overall dimensions
(mm)
Overall quality
(kg)
Volume L
Vacuum blade enema machine
Variable frequency speed regulation
7.5+0.75
three hundred and eighty
one thousand and two hundred × eight hundred × one thousand five hundred and fifty
eight hundred
two hundred
Trial operation
Before carrying out the first operation, maintenance personnel must conduct a test run to
Ensure that all functions of the machine are normal.
After closing the hopper and connecting the power supply, first check if the power cord is connected correctly. (Inspection method: First close the air circuit breaker in the distribution box, then turn on the power switch of the body, and then press the "Run" and "Vacuum" buttons in sequence. If the machine does not respond, it indicates that the three-phase power is connected incorrectly. Adjust any two of the three main power lines.)
Place the machine in a suitable position and level the four feet, requiring the hopper to be flipped to a direction no less than 1.5m away from the wall.
Connect the 380V power supply and firmly connect the ground wire to the workshop's ground wire network.
Open the hopper and check if there are any foreign objects inside the vane pump.
Install the impeller and blades (apply a little edible oil to the moving surface), position the cam, and then place the hopper back in place and press the pump cover tightly. After everything is normal, pour the filling material into the hopper.
Due to the different densities of filling materials, the filling speed used varies. Following the principle that the higher the density of filling materials, the worse the fluidity, and the slower the filling speed.
Opening and closing the lid
Cleaning
At the end of each filling process, there is a decrease in the vacuum pumping degree of the vacuum pump, which needs to be turned off
Turn off the power, loosen the clamping handle, flip the hopper over, take out the inner nails, and loosen the screws inside the impeller
Lock the bolts and use the special tool provided with the lifting wheel to lift the impeller and blade together and place them in place
Wash in water, rinse and wipe the pump chamber clean, and return the hopper to its original position. When not in use for a long time,
Please apply edible oil to the impeller, pump chamber, and blades* It is strictly prohibited to turn on the vacuum pump during cleaning; No
If the vacuum pump is easily damaged due to water ingress, we are not responsible!
9. Maintenance and lubrication
9.1 The specific use and maintenance of the vacuum pump of this machine can be found in the "User Manual" of the vacuum pump
9.2 The blade pump is a key part of the machine, and it is required to clean it carefully after each work is completed,
Handle and handle with care during cleaning and installation to avoid collisions. Abnormal sound response found during work
Timely inspection and handling.
9.3 The electrical control parts are all installed in the electrical box, and the box should be kept clean at all times. In the
Please do not directly use water to clean the box.
9.4 The sealing ring of the hopper and rotor may wear out during long-term use
If the filling is exposed, it should be replaced in a timely manner