Product Details

Level Sensor For Acid Liquid Tanks

Brand Name Wepower Electronic
Place of Origin China
Model Number UHZ

Product Features

Product Overview

     Magnetic level sensor for acid corrosive liquids  is typically used in hydrochloric acid tanks, hypochlorous acid tanks, sulfuric acid tanks, nitric acid tanks. The duct pipeis made of  UPVC, PP, or SS304 with tetrafluoroethylene (PTFE) lining . As the magnetic float level sensor is side-mounted by the tanks external , therefore avoiding the sensor contacting directly with the corrosive acid liquids . 

     Based on our rich experience , we suggest PP or PVC duct pipe for strong acid corrosive liquids when the ambient temperature and pressure as well as the measuring range is less than 2 meters , that is because the PP/ PVC pipes have the material aging problem , which can not last for long time. While the working condition is high pressure , high temperature and long measuring range , we alwaysy suggest the stainless steel 304 duct pipe with the inner PTFE lining for long lifetime .  

Technical Parameters

Product Name

 Magnetic level sensor for acid corrosive liquids 

Measuring range

150~15000mm

Accuracy

±10mm

Working pressure

Normal pressure~25MPa

Working temperature:

-200~600℃

Medium density

0.5~2.0 g/cm3

Medium density difference

≥150kg/m3 (measurement boundary)

Environmental vibration:

frequency≤25Hz, amplitude≤0.5mm

Following speed:

≤0.08m/s

Medium viscosity

≤0.4Pa.S (jacket heating can be used to improve viscosity conditions)

Process connection

flange, or the installation method and specifications specified by the customer

Installation Methods Top Mounting: suitable for underground liquid storage tanks,  level diplay on the ground; Side Mounting 

Material:

Duct Pipe : 304; 316L; PP;PVC; Stainless steel 304/316 with PTFE Lining 

Float : 304, 316L, PTFE; Titanium, PP, PVC 


Product Details

magnetic level indicator


PP magnetic level gauge


Transmitter fixed on the measuring duct pipe of the magnetic level gauge by a clamp, and the transmitter can be installed at the upper end or at the lower end. The transmitter is an electronic precision part, which is strongly affected by the environment. The normal operating temperature range is -40 to 85°C, there may be unclear display or signal interruption If the environment is harsh.


level sensor for acid liquids

 


magnetic level indicator application


magnetic float level indicator



magnetic indicator ordering


You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now