APM800 Rs485 Interface Supports Modbus Accuracy Class 0.5S/0.2S True RMS Measurements 3-Phase Electric AC Power Meter With LCD
APM800 Rs485 Interface Supports Modbus Accuracy Class 0.5S/0.2S True RMS Measurements 3-Phase Electric AC Power Meter With LCD
APM800 Rs485 Interface Supports Modbus Accuracy Class 0.5S/0.2S True RMS Measurements 3-Phase Electric AC Power Meter With LCD
APM800 Rs485 Interface Supports Modbus Accuracy Class 0.5S/0.2S True RMS Measurements 3-Phase Electric AC Power Meter With LCD
APM800 Rs485 Interface Supports Modbus Accuracy Class 0.5S/0.2S True RMS Measurements 3-Phase Electric AC Power Meter With LCD

APM800 Rs485 Interface Supports Modbus Accuracy Class 0.5S/0.2S True RMS Measurements 3-Phase Electric AC Power Meter With LCD

USD $235 - $254 /Piece

Min.Order:1 Piece

Supply Ability:
1 Kilogram / Kilograms per Month
Payment Terms:
T/T L/C Credit Card PayPal

Quick Details View All >

Brand Name:
Acrel
Place of Origin:
China
Model Number:
APM800
Operating Temperature:
-20 °C ~ +65 °C
Dimensions:
96*96*90mm

Acrel Electric Co., Ltd

Business license
Business Type: Manufacturer
Shanghai China
Main Products: Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement

Product Details

                                                       APM8xx Series AC Multi-function Smart Meter

The APM series meters are suited for measuring and displaying electrical quantities of electricity networks. The accuracy of active energy measurements corresponds to class 0.5S in accordance with the requirements of IEC62053-22.

The APM series meters offer many high-performance capabilities needed to meter and monitor an electrical installation in a compact 96 x 96 mm unit. All models include an RS-485 Modbus communication port, two digital inputs, two digital outputs, and alarming on critical conditions.

The model of APM810 is able to perform current/voltage harmonics for assessment of the power quality. In addition, the model of APM801 can offer active energy accuracy up to class 0.2S.

Expand any model with field-installable option modules that offer a choice of additional digital inputs and outputs, analog inputs and outputs, and Ethernet ports.

Picture

Description

Optional Function

● Measurement: 3-phase kWh, kVarh, kW, I, U, Hz, Cosφ, Current&Voltage Unbalance, 2~63rd Harmonic(APM810, APM830), Real-time&Max Demand, Zero-sequence Current, 4-quadrant Energy and etc
● Current Rating: -/5A AC; -/1A AC (According to CTs)
● Voltage Rating: 100V, 110V, 400V, 690V AC
 Frequency: 45~65Hz
● Measurement accuracy:
Class 0.5S (APM800,APM810)
Class 0.2S (APM801,APM830)
● Communication (Main Body): RS485 (MODBUS-RTU)
 66 alarm types and 16 external (SOE) event records
● Display: LCD Display
● Dimension: 96*96*90mm (L*W*H)
● Installation: Panel Embedded (Cut-out --92*92mm)
● Power Supply: 85~265V AC/DC; 115~415V AC/DC
● Standard&Certificate: CE

● Muti tariff energies

● 8DO+2DI

● SD card

● the second RS485

● Ethernet

 PROFIBUS-DP

● 4 channel 2M NTC temperature, measurement

● 2 channel PT100 temperature, measurement

● 1 channel temperature and humidity


Full Electric Parameters Measurement

● 3-phase (I, U, kW, kVar, kWh, Hz, cosφ)

● Current&Voltage Unbalance

● Harmonic (THD & 2~63rd)

● Real-time&Max Demand

● Extremum of this month&last month

● Zero-sequence Current

● 4-quadrant Energy

Diverse Extra Function Module

● Modular Design (Easy for Function Expansion)

● Support up to 3 Expanded Module at same time

DO/DI Switch Function Module ---MD82

● 2 DO Relay Output

● 8 DI Digital Input

● Save up to 128 pcs DO/DI Data in Main Body

● Paired with MLOG to save more DO/DI Records

SD Card Data Storage Module ---MLOG

● Expand Number of SOE Storage

● Support Storage of SD Cards up to 32GB (standard 4GB)

Extra RS485 Communication Module ---MCM

● Interface: RS485 Interface

● Protocol: MODBUS-RTU

● Support Salve&Master Mode

Ethernet Communication Module ---MCME

● Interface: RJ45 Interface

● Protocol: MODBUS-TCP/HTTP/DHCP/SMTP

● Could Serve as Serial Server

● Plus 1 Extra RS485 Interface

PROFIBUS-DP Communication Module ---MCMP

● Interface: PROFIBUS-DP Interface

● Protocol: PROFIBUS-DP

● Plus 1 Extra RS485 Interface


SOE Function (Main Body)

● Alarm Record (128 pcs records of 66 kinds&13 categories)

● DO/DI Record (128 pcs DO/DI records)

● Transient Record (800 pcs transient waveform records)

● Max Records pcs above could be expanded by SD Card

Multi-rate/Multi-tariff

● 4 Time zone

● 4 Tariff rate (Spike, Peak, Flat, Valley)

● 2 Time period list

● 14 Time period by day

Local Configuration

● Keypads HMI for Programming

● Setting through Adjustment Software

● Setting through WEB

● Setting through MODBUS communication

Technical Parameter

Value

Signal

Connection

3 phase 3 wire, 3 phase 4 wire

Frequency

45~65Hz

Voltage

Rated value: AC 100V,110V,400V,690V

Overload: 1.2 times rated value(continuous); 2 times rated value(1 second)

Power consumption: <0.5VA (per channel)

Current

Rated value: AC 1A, 5A

Overload: 1.2 times rated value(continuous); 10 times rated value(1 second)

Power consumption: <0.5VA (per channel)

Measurement accuracy

Voltage, current, and power

Class 0.5S (APM800,APM810)

Class 0.2S (APM801,APM830)

Active power

Reactive power

Class 2(APM800, APM810), Class 0.5(APM801,830)

Harmonic

1%(2~42nd),2%(43~63rd)

Switch inputs

Passive contact inputs, built-in power supply

Relay outputs

Contact type: open contact in the main part, changeover contact in module Contact capacity:3A/AC 250V 3A/DC 30V

The pulse output of energy

Output mode: Optocoupler pulse with open collector Pulse constant:4000(5A),8000(1A) imp/kWh

Analog outputs

DC 0~20mA,4~20mA,0~5V,1~5V output, accuracy class 0.5%, load resistance ≤ 500Ω

Analog inputs

DC 0~20mA,4~20mA,0~5V,1~5V input, accuracy class 0.5%

Storage card

Standard capacity:4G, TF card up to 32G capacity

Communication

RS485(Modbus-RTU)

Profibus(Profibus-DP)

Ethernet(Modbus-TCP,HTTP,DHCP)

Auxiliary power supply

Operating range: AC/DC 85V~265V or AC/DC 115~415V(P2)

Power consumption: Power consumption of the main part ≤ 15VA

Safety

Insulation resistance

>100MΩ

Electromagnetic compatibility

IEC 61000 standard (Level 4)

Protection level

IP54(Front)


3-phase 4-wire connection

via 3 extra CTs

3-phase 3-wire connection

via 2 extra CTs & 2 extra PTs








Contact Supplier

Ms. Shelly Zhang sales manager Chat Now
Telephone
86-21-18702111813
Mobile
86-18702111813
Fax
86-21-69155906
Address
No.253 Yulv Road, Jiading District, Shanghai
Whatsapp
86-18702111813

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electrical Instruments > Multimeters
Categories
Hi~