HUADA/HAWKER LPC100-48 Charging Station
CNY 20000 - 25000 /Bag
Min.Order:1 Bag
HUADA/HAWKER LPC100-48 Charging Station
HUADA/HAWKER LPC100-48 Charging Station
HUADA/HAWKER LPC100-48 Charging Station
Hawker LPC Intelligent Charging Station
Product features: This product is designed for applications such as automatic guided vehicles/electric forklifts.
The product is composed of basic power modules N+1 in parallel, which can meet the maximum power application of 24V240A/48V200A.
The entire machine adopts a controller specifically developed for the application requirements of AGV cars in automatic production lines,
Realize logic control, system protection, parameter setting, charger management, upper communication and other functions, and use a 7-inch full color touch screen to achieve human-computer interaction.
The system has the following characteristic functions:
Ultra high power, 240A@24V / 200A@48V
Hot swappable mode, N+1 redundant structure protection
Ultra high power density and compact volume
Support current expansion and upgrading
Standard efficiency up to 92%
Multiple usage modes (fast charging, interactive charging, balanced charging, maintenance charging)
Provide IO ports for system interlocking protection
Equipped with industrial communication bus (CAN/MODBUS/PROFIBUS DP)
High protection and safety level (IP54), designed specifically for industrial applications
Protective characteristics
● Overheat protection: When the internal temperature of the charger exceeds 75 ℃, the charger will shut down for protection and automatically resume charging when the temperature drops.
Short circuit protection: When an unexpected short circuit occurs at the output of the charger, the charger automatically shuts down the output. After the fault is resolved, the charger restarts charging with a delay of 10 seconds.
● Reverse connection protection: When the battery is reversed, the charging machine will cut off the connection between the internal circuit and the battery, and will not start charging, nor will there be any damage.
● Input low voltage and overvoltage protection: When the input AC voltage is below 185V or above 265V, the charger will shut down for protection and automatically resume operation after the voltage is normal.
2、 Technical indicators
Rated input voltage: AC220V ± 15%
Rated frequency: 45~65 Hz
Battery pack voltage: 48V
Full load efficiency: ≥ 93%
Maximum charging current: 100A
Uniform charging and floating charging: automatic completion
● Battery type: Lithium iron phosphate battery
● Shutdown method: automatic, or timed, or automatic shutdown after disconnecting the charging plug
Cooling method: forced air cooling
Display method: LED digital meter head, combined with LED light to indicate charging status
Mechanical impact and seismic rating: in accordance with SAEJ1378 requirements
● Protection level: IP66
Operating temperature: -5 ℃~+45 ℃
Storage temperature: -30 ℃~+70 ℃
Charging control: temperature compensation control, never overcharge or undercharge
Connector configuration: ANEN350A
Product specifications
Voltage level
24V system
48V system
model
LPC120-24
LPC180-24
LPC240-24
LPC100-48
LPC150-48
LPC200-48
power
3600W
5400W
7200W
6000W
9000W
12000W
Charging current
5-120A
5-180A
5-240A
5-100A
5-150A
5-200A
input voltage
220VAC ± 10%, 50/60Hz (optional 380VAC ± 10%)
power factor
≥ 0.99@220Vac /50A, ≥ 0.98@220Vac /25A (single module)
Dynamic adjustment rate
± 5.0% for load changes of 10-90% or 90-10%, adjustment time<200us
Load regulation
± 0.5% from 10% to 100% load
Charging voltage
16-30VDC
43-58VDC
Steady current accuracy
≤ ± 0.5%
Noise voltage
<200 mV peak, 30 MHz bandwidth,<2 mV rms phone weight
Adjusting accuracy
≤ ± 0.5%
Time accuracy
≤ ± 10S/24h
Charging parameter settings
voltage
0.01V
Current
0.1A
time
1S
aspect
Based on power
weight
Based on power
working temperature
0 ℃~45 ℃
Storage temperature
-10 ℃~40 ℃
Working humidity
Relative humidity of 10%~80%, no condensation
protect
Over current, over voltage, over temperature, reverse connection, leakage, short circuit, cut-off
communication
CAN/MODBUS/PROFIBUS DP optional
Interactive DIO
Dry contact DIO, battery contact notification, standby, charging, charging completed, fault
safety standards
IEC 60950-1
Electromagnetic compatibility standards
EN 61000-6
environment
ETSI EN 300 019-2 complies with RoHS standards
Insulation and pressure
3.0 KVAC - input to output 1.5 KVAC - input to ground 0.5 KVDC - output to ground
Mean time between failures
5 million hours
noise
50DB
The Hawker charging station adopts a floor mounted installation method.
HUADA/HAWKER LPC100-48 Charging Station