IMO 1000m3/h Ship UV Ballast Water Management System BWMS
IMO 1000m3/h Ship UV Ballast Water Management System BWMS
IMO 1000m3/h Ship UV Ballast Water Management System BWMS
IMO 1000m3/h Ship UV Ballast Water Management System BWMS
IMO 1000m3/h Ship UV Ballast Water Management System BWMS

IMO 1000m3/h Ship UV Ballast Water Management System BWMS

USD $50000 - $90000 /Set

Min.Order:1 Set

Supply Ability:
1000 Set / Sets per Month
Port:
Shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
15 days

Quick Details View All >

Brand Name:
GOHI
Place of Origin:
China
Model Number:
LS1000

Chongqing Gohi Marine Equipment Co., Ltd.

Business license
Business Type: Trading Company
Chongqing China
Main Products: Lifeboat ,rescue boat ,ballast water management system ,external fire fighting fifi system ,marine sewage treatment plant ,life jacket ,marine oily water separator ,marine evacuation system ,bow thruster ,azimuth thruster ,life raft ,solvent recovery machine

Product Details

Product Introduction

IMO 1000m3/h Ship UV Ballast Water Management System BWMS uses advanced full-automatically backwash filter, with high-efficient medium-pressure UV radiation technology to accomplish the online treatment of ship ballast water. LS BWMS has been type approved in accordance with MEPC.300(72) aka new G8 and BWMS Code by China Classification Society (CCS) and fully meet “D-2” discharge standard.

IMO 1000m3/h Ship UV Ballast Water Management System BWMS offers simple operation and simple maintenance, dual-directional (local and remote) automatic control, friendly interface, and easy manipulation. The system is in unit-modular design with a capacity range from 150~3000m³/h, thus providing flexible and simple installation on small tonnage vessels while multiple units assembled installation on large-tonnage vessels. Therefore, it takes no large space. Meanwhile, the system is also suitable for old ships with narrow space.

The filtration plus UV radiation method takes no additional contamination with no adding or reserving chemicals. The entire system is completely closed in operation thus causing no hazards of radiation or noise to the crew.

System control can be realized through the optional remote control box for local and remote two-way control. Meet on-site and remote operation. The whole process is convenient, intuitive and reliable. The system working data can be stored and recorded to reflect the operation of the equipment during the ship's voyage, and can provide working operation records according to the requirements of the inspection department, with long-term traceability.


Working Principle

The System includes Filter, UV Reactor, Control Unit, Power Cabinet, and Electric Valves, monitoring equipment, sampling device and pipeline. General working modes include ballasting and de-ballasting processes, as well as ballast stripping and emergency bypass.

Technical Specification

ModelLS-1000
Capacity ( m3/h):1000
Filter × Qty:LSF-1000 ×1
UV Reactor × Qty:LSV-1000 × 1
Control Unit × Qty:LSC-1L × 1
Power Cabinet × Qty:LSP-1 × 1
Rated Power (kW)*:~18

Power Consumption


Component

Power Consumption (kW)

Continuous loads

Intermittent loads

Power cabinet130.5
 Control Unit1.00.5
Backflush pump/3
 sub-total144
 Total18


Working Conditions

Working Conditions

Humidity

095

(Equipment in Engine Room)

Ambient temperature

055

Seawater temperature

035

Slope & Swing

Static

 All directions ≤22.5°

Dynamic

 All directions ≤22.5°

Electromagnetic

Compatibility

Voltage floating

±10%

Instantaneous voltage floating

±20%

Frequency floating

±5%

Instantaneous frequency floating

±10%

(Recover in 3 seconds)

Power Supply

380(440)V, 50(60)Hz, 3Φ

Fresh Water

About 2.0 m3 / time

For replacing seawater in BWMS when storage

General Requirement of Relevant Piping

Shipbuilding standard are mandatory regarding relevant piping, sampling facilities and pipes used along for firefighting, and shall be easy to clean, inspect, service and operate. The freshwater piping shall not be mixed up with seawater and piping design pressure shall not exceed 1.0MPa.

Electrical

Requirements

The cable connected to the system shall be approved marine cable.


Main Model List


ModelRated Capacity (m3/h)Capacity Range (m3/h)Power (KW)Weight (Ton)Length (mm)Width (mm)Height (mm)
BWS-15015050-150221.5260010001700
BWS-250250150-250262.2240021001800
BWS-350350250-350352.3240021001900
BWS-500500350-500502.4240021002000
BWS-850850500-850743.0310024002300
BWS-11501150850-1150983.3350025002300
BWS-150015001150-15001234.1450030002400
BWS-170017001500-17001465.9500031002300
BWS-230023001700-23001946.5550038002300
BWS-300030002300-30002438.2650045002400


Automatic Backflush Filter as the first step of the system is specifically designed for ballast water screening, which has fine mesh elements aiming to remove the microbe and sediments with size larger than 50μm.

Filter adopts the up-to-date concept of auto backflush to efficiently fulfill filtering and screen-cleaning at the same time, backflush automatically starts based on differential pressure while filtration continues, with no other manual on-site operations needed.

Filter functions only in Ballasting process while it is bypassed in De-ballasting process and By-pass process.