RMRS Approved 30 Persons Marine Sewage Treatment Plant STP
USD $5000 - $10000 /Set
Min.Order:1 Set
Chongqing Gohi Marine Equipment Co., Ltd.
Application
RMRS Approved 30 Persons Marine Sewage Treatment Plant STP belongs to the key devices for prevention of prollution form ships in seas and oceans according to the revised Annex IV of the International Convention of the Prevention of Pollution(MARPOL 73/78).This device is applicable to treat the sewage,which means human body wastes and the wastes from the toilets on vessels and which is also called "black water".
The device also can be used in terrestrial sewage,besides in ship vessels and oil platform.The water quality after treatment can reach the national reuse water quality requirements.It's also applicable to treat the galley,shower drainage which is called"gray water" on condition that the "gray water" is pretreated and these should select a bigger capacity model to match with.
Features
ABS, CCS,BV,EC Approval
IMO Approval
Meet resolution of MEPC.159.(55) enacted on October2006.
Used for seaport,dock,industry,petroleum ,various vessels
Principle Description
The waste water Sewage treatment plant adopts the principle of Activated Sludge,Bio contact Oxidation and Membrane Biological Reactor(MBR) to digest organic pollutant.MBR can treat organic pollutant efficiently,drastically and cleanly to ensure the effluent can meet the requirements of the resolution MEPC.159(55) and other much harsher requirements.
Models of marine waste water sewage treatment plant
GRCM-15 (15 persons)
GRCM-20 (20 persons)
GRCM-25 (25 persons)
GRCM-30 (30 persons)
GRCM-40 (40 persons)
GRCM-400 (400 persons)
Specification
1.Adopting horizontal circular design,ellipse closures on both ends,pressure resistance and compact structure
2.The device is adopted auto-control,and compliance with the requirment of 24h unattened cabin.
3.Adopting the "MBR" technology,devices allow to the narrow size,and solve the conflict of small space of carbin,but big volume of device.
4.The intermittent aeration in bio-membrane tank and hollow fiber membrane tank,form the process of "aerobic-anoxic",and resolve the problem of "nitrogen and phosphorus removal.
5.The device is adopting the principle of "air lifting" to transfer the sludge from sediment tank and membrane tank to aeration tank,meantimes the "pump stops and air never stopped",so as the scale on the membrane surface comes dowm.Due to back flushing and clean the membrane "online" usd technol;oge patent.
6."Online" cleaning technology,making the dirt on membrane off automatically,recover membrane flux.It can be solved the problem of openning the cleaning or replacement of the membrane difficultly caused by the small space in cabin.
7.The effluent after further treatment can be reached at the requirment of "water recovery".
Model | SWCM | ||||||||
10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | ||
Treated Load | Average Load (L/d) | 840 | 1190 | 1540 | 1890 | 2310 | 3080 | 3780 | 4480 |
Peak Load (L/h) | 105 | 149 | 193 | 237 | 289 | 385 | 473 | 560 | |
Organic Load (kgBOD5/d) | 0.42 | 0.595 | 0.77 | 0.945 | 1.155 | 1.54 | 1.89 | 2.24 | |
Rated Capacity(P) | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | |
Max Capacity(P) | 12 | 17 | 22 | 27 | 33 | 44 | 54 | 64 | |
Electricity | AC380V-50Hz / AC440V-60Hz | ||||||||
Power(kw) | 2.25 | 2.25 | 2.5 | 2.5 | 2.5 | 3 | 3 | 3.5 | |
External Dimensions Length×width×height | 1350 × 1200 × 1370 | 1850 × 1200 × 1400 | 1660 × 1400 × 1550 | 1890 × 1400 × 1560 | 1980 × 1500 × 1650 | 2270 × 1600 × 1700 | 2300 × 1700 × 1820 | 2650 × 1700 × 1830 | |
Weight | Dry weight (kg) | 900 | 1000 | 1000 | 1100 | 1200 | 1300 | 1450 | 1600 |
Wet weight (kg) | 1775 | 2283 | 2640 | 2740 | 3500 | 4400 | 5073 | 5270 | |
Discharge Standard | TSS<35mg/L;BOD5<25mg/L;COD<125mg/L;Colichin<100/100ml;PH:6-8.5 |
Model | SWCM | ||||||||
80 | 100 | 120 | 150 | 200 | 250 | 300 | 400 | ||
Treated Load | Average Load (L/d) | 6020 | 7700 | 9100 | 11200 | 14700 | 18200 | 23100 | 30800 |
Peak Load (L/h) | 753 | 963 | 1138 | 1400 | 1838 | 2275 | 2888 | 3850 | |
Organic Load (kgBOD5/d) | 3.01 | 3.85 | 4.55 | 5.6 | 7.35 | 9.1 | 11.55 | 15.4 | |
Rated Capacity(P) | 80 | 100 | 120 | 150 | 200 | 250 | 300 | 400 | |
Max Capacity(P) | 86 | 110 | 130 | 160 | 210 | 260 | 330 | 440 | |
Electricity | AC380V-50Hz / AC440V-60Hz | ||||||||
Power(kw) | 4 | 4 | 4 | 6 | 6 | 7 | 9 | 11 | |
External Dimensions Length×width×height | 2790 × 1900 × 2050 | 2706 × 2000 × 2200 | 3000 × 2000 × 2200 | 3080 × 2200 × 2300 | 3630 × 2200 × 2350 | 3880 × 2400 × 2570 | 4780 × 2400 × 2600 | 5980 × 2400 × 2600 | |
Weight | Dry weight (kg) | 1850 | 2200 | 2300 | 2800 | 3000 | 3300 | 3700 | 4200 |
Wet weight (kg) | 6517 | 8268 | 9166 | 11340 | 13267 | 16538 | 20357 | 25417 | |
Discharge Standard | TSS<35mg/L;BOD5<25mg/L;COD<125mg/L;Colichin<100/100ml;PH:6-8.5 |