Rectifier module R48-2900U function
Input 220V 50Hz, large working range 85~290Vac
L2. Output 42~58Vdc, software adjustable, large output power 2900W
L3. Module software current sharing, with a non-uniformity of less than 3%
L4, CAN bus communication, can connect up to 48 in parallel
L5. It has multiple protection functions such as AC overvoltage/undervoltage, DC overvoltage, over temperature, short circuit, etc
L6. It has LED working status indication and multiple alarm indication functions
L7. Module hot plug, plug and play, without any parameter settings.
l
8. Module dual power supply
Characteristics of rectifier module R48-2900U:
1. Input voltage wide range Power limiting: Power derating Input voltage range: 85Vac~176VA
Not working withstand large static voltage: 415Vac
Rated input current: < 16A@2900W
Large input current: < 19A@2900W /176Vac
Input impulse current:<30A
2. Output power limiting, short circuit current limiting
3. Hot plug, adaptive
4. Dual temperature power limiting, over temperature protection
5. DSP software current sharing
Difference between l and average current<± 1.5A
L module internal processor DSP current sharing control
– Average current mode
– Constant voltage control
– Module autonomous control
– Module failure does not affect current sharing
– Non current sharing alarm
Yellow indicator: current sharing error exceeds 8A
• Red indicator: No output or error exceeding 10A
Large enough to be connected in parallel with 48
L No current sharing line required
Use the CAN bus to ensure that all modules communicate normally
6. Overvoltage shutdown, automatic restart
Hardware overvoltage protection:
– 59.5V。 Manual startup is required.
Software overvoltage protection
– Monitoring setting: 56-59V
There are two software overvoltage protection modes that can be selected through background maintenance software:
A. Primary overvoltage lock mode
When the output reaches the software protection point, the module shuts down and maintains, requiring manual intervention before resuming operation;
B. Secondary overvoltage lockup mode
When the output reaches the software protection point and the output current is greater than 5A, the module restarts after shutting down for 5 seconds. If a second overvoltage occurs within the set time (the default is 5 minutes, which can be set), the module shuts down and remains, requiring manual intervention before starting up.
If the output current of the rectifier module is less than 5A (10% of the rated output), the rectifier module does not shut down.
Manual intervention method: reset the rectifier module by monitoring the module or detach the rectifier module from the power system.
7. Current slow start