ADW210 Multi Channel AC Energy Meter
ADW210 series multi-loop power meter is mainly used for the measurement of all electric parameters of three-phase circuit.Colleagues can select the current input of the maximum four circuits.
ADW2XX series products are connected by split core current transformer, easy to install on site, and realize remote wireless communication through wireless communication module.
Products Description
Note:
1.Optional external suction cup antenna,standard wiring length:2m
2.The extended function Module can be selected at most simultaneously MK+MTL+AWT Wireless Communication Module
3.It is recommend that the distance between AKH-0.66/K-∅10N installation postion and the primary side transformer should be more than 1 meter ;
4.Leakage current transformer is recommended model;
Optional function | ||||||||
Module | Function | Note | ||||||
/MTL | 12 external NTC temperature measurement + 4 residual current measurement | Contact us for more product information and price information. | ||||||
/MK | 12DI+4DO |
Multi-circuits Monitoring
● Monitor up to 4×3-phase circuits in total
● Paired CTs with specs of 5A/1.25mA; 100A/20mA; 400A/100mA or
600A/100mA
● External CTs Connectwith ADW210 Main Body thrrough RJ12 Interface
● Monitor up to 4×3-phase circuits in total
● Paired CTs with specs of 5A/1.25mA; 100A/20mA; 400A/100mA or
600A/100mA
● External CTs Connectwith ADW210 Main Body thrrough RJ12 Interface
Expanded Communication Module --- AWT100
● 4G (Global general module)
● WiFi
● LoRaWAN
● LoRa
● NB-IoT
● 4G (Global general module)
● WiFi
● LoRaWAN
● LoRa
● NB-IoT
Cable Temperature&Residual Current Measurement Module --- MTL
● Temperature Measurement:-20℃~+100℃
● Residual Current Measurement:10~3000 mA
● Accuracy:Temperature:± 2℃; Residual Current:1% (Class 1)
● Temperature Measurement:-20℃~+100℃
● Residual Current Measurement:10~3000 mA
● Accuracy:Temperature:± 2℃; Residual Current:1% (Class 1)
DO/DI Switch Extra Function Module --- MK
● 12 channel DI (Digital Input)
● 4 channel DO (Digital Output)
● 12 channel DI (Digital Input)
● 4 channel DO (Digital Output)
Technical Parameter
Function | Description | |||||||
Energy Measurement | kWh (positive and negative) | |||||||
kvarh (positive and negative) | ||||||||
A,B,C three-phase positive kWh | ||||||||
Electric Parameter | U, I, P, Q, S, PF, Hz | |||||||
Harmonic | 2-31st voltage and current harmonic | |||||||
Communication | RS485 (MODBUS-RTU); baud rate 1200~38400 | |||||||
Key Programming | 4 keypads to set communication and parameters | |||||||
Display | LCD display, 8 digits | |||||||
LED Alarm | Over-voltage, over-current, interruption phase | |||||||
Data Log | Maximum demanded kWh and the time it happened. | |||||||
SOE | up to 200 pcs, record on-off status of DO/DI | |||||||
Pulse Output | Active optocoupler pulse output with open collector | |||||||
Multi-rate/Tariff | 4 time zones & 12 time periods | |||||||
Expanded Module | Description | |||||||
AWT100 Communication Module | 4G (Global general module) | |||||||
2G | ||||||||
LoRaWAN (868 MHz, 923MHz) | ||||||||
LoRa (460~510 MHz) | ||||||||
NB-IoT | ||||||||
-MK Swtich Module | 12 × DI (input) | Dry contact input with built-in power supply | ||||||
4 × DO (output) | Relay normally open contact output; rating AC 250V/3A ,DC 30V/3A | |||||||
Power Supply | DC 12V;consumption:≤1W;RJ45 interface | |||||||
Communication | RJ45 interface; MODBUS-RTU (communication with main body) | |||||||
-MTC Temperature & Residual Current Measuring Module | Temperature Measurement | -20℃~+100℃ | ||||||
Residual Current Measurement | 10~3000 mA | |||||||
Accuracy | Temperature:± 2℃; Residual Current:1% (Class 1) | |||||||
Power Supply | DC 12V;consumption:≤1W;RJ45 interface | |||||||
Communication | RJ45 interface; MODBUS-RTU (communication with main body) | |||||||
Parameters | Description | |||||||
Input | Voltage | AC 3×220V/380V | ||||||
Overload: 1.2 times of rated value (continuous); 2 times of rated value / 1s | ||||||||
Power consumption:≤ 0.5VA | ||||||||
Current | AC 5A、100A、400A、600A;(external open-type CT) | |||||||
Overload: 1.2 times of rated value (continuous); 10 times of rated value / 1s | ||||||||
Power consumption:≤ 0.5VA | ||||||||
Frequency | 45~65Hz | |||||||
Measuring Accuracy | Voltage&Current | Class 0.5 | ||||||
Active Power | Class 1 | |||||||
Reactive Power | Class 2 | |||||||
Frequency | 0.05Hz | |||||||
2~31st harmonic | ± 1% | |||||||
Auxiliary Power | AC/DC 85~265V;consumption≤10VA; | |||||||
EMC | Better than grade 3 | |||||||
Safety | Withstand Voltage | >AC 2000V/1min | ||||||
Insulation Resistance | >100MΩ | |||||||
Environment | Working Temperature | -20℃~+60℃ | ||||||
Storage Temperature | -40℃~+70℃ | |||||||
Humidity | ≤95% (No condensation) | |||||||
Altitude | ≤2500m | |||||||
Paired CT | Primary Current | Secondary Current | Aperture(Hole size) | Accuracy Class |
AKH-0.66/K-φ10N | 5A | 1.25mA | 10mm | Class 0.5 |
AKH-0.66/K-φ16N | 100A | 20mA | 16mm | Class 0.5 |
AKH-0.66/K-φ24N | 400A | 100mA | 24mm | Class 0.5 |
AKH-0.66/K-φ36N | 600A | 100mA | 36mm | Class 0.5 |
AKH-0.66-L-45 (for residual current) | / | / | / | Class 1 |
Wiring Illustration
3-phase 4-wire Wiring of ADW210 monitoring 4 3-phase Circuits
Wiring between ADW210 Main Body and MTL&MK Extra Function Module through RJ45 Interface
Wiring between 1 ADW210 Main Body and 1 AWT100 Communication Module
(Attention: In the connection between 1 ADW210 and 1 AWT100 through RJ45 interface, we don't need Auxiliary Power Supply for AWT100)
Wiring between more than 1 ADW210 Main Bodies and 1 AWT100 Communication Module
(Attention: In the connection between more than 1 ADW210 and 1 AWT100 through RS485 Serial Ports, we need DC24 or DC12V AuxiliaryPower Supply for AWT100)
Dimension & Installation
Solution Structure
Certification
Company Profile
FAQ