ADL400 ac power energy meter 3 phase to monitor kwh MID certificate with rs485 modbus
ADL400 ac power energy meter 3 phase to monitor kwh MID certificate with rs485 modbus
ADL400 ac power energy meter 3 phase to monitor kwh MID certificate with rs485 modbus
ADL400 ac power energy meter 3 phase to monitor kwh MID certificate with rs485 modbus
ADL400 ac power energy meter 3 phase to monitor kwh MID certificate with rs485 modbus

ADL400 ac power energy meter 3 phase to monitor kwh MID certificate with rs485 modbus

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Acrel Electric Co., Ltd

Business license
Business Type: Manufacturer
Shanghai China
Main Products: Hall Sensor ,Split Core Current Transformer ,AC Energy Meter ,DC Energy Meter ,IoT Wireless Power Meter ,PV/Solar Inverter Energy Meter ,Data Center Power Meter ,Wireless Temperature Monitoring System and Sensors ,Medical IT Products ,City Utility Tunnel Moter Protector ,Electrical Insulation Safety Products ,Energy Quality Improvement

Product Details

ADL400 Three-phase DIN Rail Energy Meter
ADL400 three phase electric meter is designed for three phase energy measurement on low voltage system.The meter meet the related technical requirements of electronic meter in the IEC62053-21,IEC62053-22 standards.
Products Description


● Measurement: 3-phase AC kWh, kVarh, U, I, P, Q, S, PF, F and etc
● Accuracy: 0.5% (kWh)
● Frequency: 45~65Hz
● Rated Voltage: 3x380~456Vac L-L (direct connect); 3x100~120Vac L-L (via PTs)
● Rated Current: 3x10(80)A AC (direct connect); 3x1(6)A AC (via CTs)
● Communication: RS485 (MODBUS-RTU)
● Multi-rate: 4 Tariff Rates and etc
● Data Function: Frozen Data,Max Demand,etc
● Harmonic: 2~31st and total Harmonic
● Standard&Certificate: IEC; CE;CE-MID; EAC
Diverse Electric Parameters Measurement
● kWh (3-phase positive Kilowatt-hours)
● kVarh (Kilovar-hours)
● Harmonic (2~31st voltage¤t)---Standard
● U (3-phase Voltage)
● I (3-phase Current)
● P (Power)
● Q (Reactive power)
● F (Frequency)
● S (Apparent power)
● PF (Power factor)
Multi-rate/Flexible Tariff
● 4 Time zone
● 4 Tariff rate (Spike, Peak, Flat, Valley)
● 2 Time period list
● 14 Time period by day
● Data Frozen (last 48 months or last 90 days)
● Max demand and occurrence time
HMI for Common Configuration
● PT or CT ratio
● Wiring methods (3P4W or 3P3W)
● Back linght time
● RS485 (MODBUS-RTU) communication setting
Technical Parameter
1.Function description
Function
Function description
Function provide
Measurement of kWh
Active kWh (positive and negative)
Reactive kWh (positive and negative)
A. B, C split phase positive active energy
Measurement of electrical parameters
U、I
P、Q、S、PF、F
Measurement of harmonics
2~31ST Voltage and current harmonic
LCD Display
12 bits section LCD display, background light
Key programming
3 keys to communication and set parameters
Pulse output
Active pulse output
Multi-tariff and functions
Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates

Max demand and occurrence time
Frozen data on last 48 months, last 90days
Date, time
Communication
Communication interface: RS485, Communication protocol: MODBUS-RTU

2.Technical parameter
Project
Performance parameter
Specification
3 phase 3 wires, 3 phase 4 wires
Measurement


Voltage
Reference voltage
3×100V3×380Vac、3×57.7/100Vac、 3×220/380Vac (Can normally work under 1.2 times of rated voltage)
Consumption
<10VA(Single phase)
Impedance
>2MΩ
Accuracy class
Error±0.2%
Currnt
Input current
3×1(6)A, 3×10(80)A
Consumption
<1VA Single phase rated current
Accuracy class
Error±0.2%
Power
Active, reactive, apparent power, error±0.5℅
Frequency
45~65Hz,Error±0.2%

Metering
Energy
Active energy(Accuracy class: 0.5) reactive energy(Accuracy class 2)
Clock
≤0.5s/d
Digit signal
Energy pulse output
1 active photocoupler output

Pulse
Width of pulse
80±20ms
Pulse constant
400imp/kWh,10000imp/kWh(Correspond with the basic current)
Communication
Interface and communication protocol
RS485:Modbus RTU
Range of Communication address
Modbus RTU:1~ 247;
Baud rate
1200bps~19200bps
Environment
Working temperature
-25℃~+55℃
Relative humidity
≤95℅(No condensation)
Wiring Illustration

PIN/Terminal Overview of ADL400 (Direct Connect Type)

3-phase 4-wire via direct connect

3-phase 3-wire via direct connect

PIN/Terminal Overview of ADL400 (CT Operated Type)
3-phase 4-wire CT operated
3-phase 3-wire CT operated
Dimension & Installation
(Current Input via Direct Connect)
(Current Input via CTs)
Solution Structure
Certification
Company Profile
FAQ

Contact Supplier

Ms. Shelly Zhang sales manager Chat Now
Telephone
86-21-18702111813
Mobile
86-18702111813
Fax
86-21-69155906
Address
No.253 Yulv Road, Jiading District, Shanghai
Whatsapp
86-18702111813

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electrical Instruments > Energy Meters
Categories
Hi~