IEC60065 Figure 9 Test plug for mechanical test on antenna coaxial sockets
USD $100 - $110 /Piece
Min.Order:1 Piece
Shenzhen Jusdatest Instrument Co.,Ltd
UL499 Figure 6.4 uninsulated live part or film-coated wire PA180、PA190 Probe
IEC/EN 60335-2-6 Figure 104 Test Probe for measuring surface temperature rise
CSA C22.2 NO.113 Clause 5.2.6.1 and 5.2.6.2 Fans and Ventilators uninsulated live part test probe
IEC60335-2-24 Figure 102 cooling system components Scratching Tool
IEC60065 Figure 9 Test plug for mechanical test on antenna coaxial sockets
Antenna coaxial Test plug
According to IEC60065 Figure 9 standard, Antenna coaxial sockets mounted on the apparatus and incorporating parts or components which isolate hazardous live parts from accessible parts, shall be constructed so as to withstand such mechanical stresses as may be expected in the intended use.
Compliance is checked by the following tests, which are made in the order given.
After these tests, the apparatus shall show no damage in the sense of this standard.
Endurance test
A test plug as shown in Figure 9 is inserted and withdrawn from the socket 100 times. Care is to be taken not to damage the socket intentionally during insertion and withdrawal of the test plug.
Impact test
A test plug as shown in Figure 9 is inserted into the socket and three successive blows from the spring-operated hammer according to IEC 60068-2-75 are applied with a kinetic energy just before impact of 0,5 J to the same point on the plug in the most unfavourable direction.
Torque test
A test plug as shown in Figure 9 is inserted into the socket and a force of 50 N is applied for 10 s, without jerks, at right angles to the axis of the plug, the radial direction of the force being such as to stress those parts of the socket which are likely to be weak. The force is determined by using, for example, a spring balance attached by means of the hole in the test plug.