Non Contact Test Gauge BS1363-2 Figure 14 For Socket-outlet Checking
USD $250 - $280 /Unit
Min.Order:1 Unit
Shenzhen Jusdatest Instrument Co.,Ltd
Noncontact Test Gauge BS1363-2 Figure 14 For Socket-outlet Checking
On insertion of a plug into a socket-outlet, the travel of the end of either current-carrying pin from the front face of the socket-outlet to the first point of contact with the appropriate socket contact, in any position the socket contacts may occupy, shall be not less than 9.6mm
Conformity shall be checked by inspection and the use of the gauge shown in Figure 14 and the circuit shown in Figure 13. Neither indicator shall light.
Figure NO: | Description | QTY.(piece) |
Figure 1 | Test Pin with 5N force | 1 |
Figure 2a.2b | Apparatus for mechanical strength test on resilient covers | 1 |
Figure 5 | Gauge for plug pins | 1 |
Figure 6 | Apparatus for testing plug cover fixing screws | 1 |
Figure 7 | Mounting plate | 1 |
Figure8 | Plug pin deflection test apparatus for resilient plugs | 1 |
Figure 10 | Apparatus for pressure test at high temperatures | 1 |
Figure 11 max/min | GO gauge for socket-outlet | 2 |
Figure 12 | Contact test gauge | 1 |
Figure 14 | Noncontact testgauge | 1 |
Figure 15 | Turning moment gauge | 1 |
Figure 16a.16b | withdrawal pull gauge for effectiveness of contact | 2 |
Figure 17a/17b | Test apparatus for temperature rise test and the dummy front plate | 1 |
Figure 19 | Solid link for test on fuse clips | 1 |
Figure 23 | Apparatus for pressure test | 1 |
Figure 29 | Calibration of calibrated link | 1 |
Figure 30 | Test plug for temperature rise | 1 |