HC-R032 Vet Doppler Blood Pressure Monitor for animals Doppler Blood Pressure Meter for Pet
Negotiable
Min.Order:1
HC-R034 20ml Veterinary Syringe Injection for Animal Plastic Steel Poultry Syringe
HC-R035 Veterinary Disposable Skin Stapler Medical Surgical Stapler for Animal or Pet
HC-R038 Veterinary Equipment Hair Dryer Machine Hair Dry Device for Big Pet
HC-R039 Small Dog Cat Used Hair Dryer Machine Hair Dry Device for Small Pet
HC-R041 Animal Blood Pressure Monitor BP Monitor for pet/dog/cat with Different Cuffs
HC-R032 Vet Doppler Blood Pressure Monitor for animals Doppler Blood Pressure Meter for Pet
Features for HC-R032 Vet Doppler Blood Pressure Monitor for animals Doppler Blood Pressure Meter for Pet:
Technical Specification
Imported manometer in high quality 1.Ultrasonic probe in 8.0 MHz |
Operation of the Doppler blood pressure meter
1. Inflation : Close the valve and then slowly press the gasbag 3. the connection and loosen of the cuffs: connect the cuffs loose the cuffs as the following pictures show. |
Procedures to test pets blood pressure
1.Cutting off fur on volar pad especially fur beneath the first toe and the cleaner, the better. And then smear couplant on the midline of the foot. 2.Smearing much couplant on probe and put the probe on the midline. Then you can hear sound like "so -so -so".If not ,please remove the probe till the sound can be heard . 3.When pets in examination in the section of outpatient ,they are always in tension .At this time ,It is advice to do the examination with 3 medical staffs :one person is to keep pets quiet , one is to use the probe to find pets pulse and the third person is to inflate and deflate the pressure meter . When monitoring pets in operation, there is needing only one person to do blood pressure meter every 5-10 minutes. 4.Cuff should be placed above the pet forelimb wrist (proximal to the heart ).The indicatrix on the end of cuff should be in the range of the circumference. If not,the tested blood pressure will be much higher (the cuff is large compared with the limb ) or much lower ( the cuff is small compared with the limb ) 5.Close the walve and begin the inflation. When you do not hear the sound like "so-so-so",continue to inflate 20mmHg more and then open the walve and begin to record the systolic pressure . 6.When in slow and continuous deflation, diastolic pressure can be recorded .However ,diastolic pressure is easily affected by many factors such as probe's position ,degree of tightness and so on so that it is not easy to hear the sound of the diastolic pressure . And this is due to the Doppler theory. But a experienced doctor with many times practice may can test the diastolic pressure . 7. It is advice to do the examination in room with heating installation in winter because room temperature is below 10 degree or pets'skin temperature is too low , the examination will be influenced and it is not easy to hear the sound of "so -so -so". I f pets are too small or their vessels are narrow ,it is usual that blood flow can not be heard . 8.The usual blood pressure range for cats and dogs is from 110mmHg to 160mmHg . |
Notes
Probe: Please turn off the power immediately after usage. The probe should be protected carefully.Do not crash and collide the probe(the probe is very expensive ) with other things. Avoiding to damage the chip in the probe . Couplant: It is not allowed to use ECG viscose,baby oil and other oils except couplant . Because those oil such as ECG viscose,baby oil will corrode and damage the probe. Battery: When power light become dark and speaker stop work ,it is necessary to charge the battery . |
Specifications :
1.Measuring range:0mGs-199.9mGs 2.Frequency of the probe: 8.0MHz 3. Specification of the blood pressure cuff Range: No.1 4.2cm-7.1cm No.2 5.4cm-9.1cm No.3 6.9cm-11.7cm No.4 9cm-13cm No.5 12cm-16cm 4. Rechargeable battery voltage:7.4V 1500mAh 5. AC input: 100-240V 50/60Hz DC output DC8.4V,1000mA 6. Continuous working time :> 8 hours |
Cleaning
1.Probe :a.Wipe off viscose softly with a napkin after usage
|
Pictures for
A: Firstly we confirm product details and then send the Proforma Invoice,
You make payment to us through Alibaba Trade Assurance or T/T, Western Union or MoneyGram,
after we confirm your payment then ship the product to you once finished production.
A: For disposable material,We have our own MOQ,For our
our MOQ:1pc,
A: For most products the warranty is for 12 months, some products we provide 18 months warranty.
For HC-R032 Vet Doppler Blood Pressure Monitor for animals Doppler Blood Pressure Meter for Pet
A: Generally it is 5 working days if goods in stock. within 10 working days if the goods need production, And also the delivery time depands on quantity.
For HC-R032 Vet Doppler Blood Pressure Monitor for animals Doppler Blood Pressure Meter for Pet
A: The shipping way normally depand on your quantity,total CBM and weight.
We have our own shipping company to provide best shipping cost and efficient way.