cooling tower fill media 305mm 610mm oblique wave PVC sheet for cooling tower
Cooling Tower PVC Fill, also called cooling tower infill film media. It is one of the most important components in cooling tower. It’s function is increase the exchange area of the gas and working fluid in order to achieve the requested cooling requirement. The working fluid was distributed onto the cooling tower PVC fill and spread into a thin film uniformly, by increasing the air-media interface and allowing waste heat to evaporate at an accelerated rate.
The heat resistance is the main factor influencing the cooling efficiency for the cooling tower PVC fill. And the quality of the raw material used for producing cooling tower PVC fill will influence the cooling tower fill's service time. Lanyu always adapt the high quality cooling tower PVC fill for the cooling tower.
This type cooling tower PVC fill is designed for the factory-assembled counterflow cooling towers.
Material | Sheet Spacing | Flute Angle | Media Pack Sizes: Depth(D), Width(W), Length(L) | Pitch | Sample | ||
PVC/PP | 0.75 in (19 mm) | 31° | Minimum | Maximum | Standard | ||
PVC/PP | D: 6 in (153 mm) W: 6 in (153 mm) L: 1 ft (305 mm) | D: 24 in (610 mm) W: 24 in (610 mm) L: 12 ft (3658 mm) | D: 12 in (305mm) or 24 in (610mm) W: 12 in (305mm) or 24 in (610 mm) L: 4 ft (1220 mm), 6 ft (1829 mm), 8 ft (2439 mm) or 10 ft (3048 mm) |
cooling tower fill media 305mm 610mm oblique wave PVC sheet for cooling tower
• Bevel Tips promotes drainage at fill pack interfaces. Note: Packs are always installed with Bevel Tips at bottom of pack.
• Patented "MA"(Mechanical Assembly) Technology for glue-free packs.
• Engineered microstructure for improved water distribution and thermal mixing
• High thermal performance
• Improved water distribution
• Proprietary edge trim that directs water to both sides of sheet
• Material meets Cooling Tower Institute (CTI) Standard 136
• Available in PVC
Advantages for Lanyu PVC fill for cooling tower:
Good chemical stability, anti-acid, anti-alkali, high cooling efficiency, small ventilation resistance, large cooling area etc.
How shall we choose the PVC fill for the cooling tower?
method,we advise to use the suitable thickness. If the width is less than 1.22meter, we advise to use the thickness less than 0.38mm; if the thickness is more than 1.22meter, such as 1.52meter, we advise the thickness should be more than 0.38mm. It is like apaper. If the width is very large, the thickness should be thick enough to bear the weight and strength.