CC-PAON01
1041 - 2261 /Piece
Min.Order:1 Piece
Temporal Ming sheng automation equipment co., LTD
Brand:HONEYWELL
Type:CC-PAON01
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
Speed priority is again automatically selected if Extr/Adm control is disabled, the generator breaker opens, or the utility tie breaker opens. Manual Priority Enabling The 505E only accepts an Extr/Adm priority select command if all related permissives are met (see enable permissive list above). An Extr/Adm priority enable (select) command may be given from the 505E keypad, a contact input, or through Modbus. The last command given from any of these three sources dictates the priority selected. When a contact input is programmed to function as an Extr/Adm priority select command a closed state represents Extr/Adm priority and an open state represents Speed priority. This contact can either be open or closed when a 505E ‘RUN’ command is given. If the contact is open it must be closed to select Extr/Adm priority. If the contact is closed when a trip condition is cleared, it must be opened and re-closed to select Extr/Adm priority. The priority selected can be viewed by pressing the “CONT” key then the Scroll down key. Optionally a relay can be programmed to externally indicate the priority selected. To select and de-select Extr/Adm priority from the 505E’s keypad, press the “CONT” key to view the control screen, then press the Scroll Down key once to display the Priority Status Screen. With all priority permissives met (listed above) press the “Yes” key to select Extr/Adm priority, or press the “No” key to de-select Extr/Adm priority. If a related permissive is not met when an Extr/Adm priority select/deselect command is given the priority will not be transferred and an “Unable to transfer priority” message will be momentarily displayed.
The 505E has three turbine start modes (manual, semi-automatic or automatic) from which to choose from. One of these start modes must be programmed to perform a system startup. Once a ‘RUN’ command is issued, the speed setpoint and HP valve limiter are manipulated automatically by the 505E or manually by the operator, depending on which start mode is selected. After a turbine start has been completed, turbine speed will be controlled at a minimum controlling speed. The minimum controlling speed may be idle if idle/rated is being used, low idle if the auto start sequence is used, or minimum governor if neither idle/rated or auto start sequence is used.