PFSA140 3BSE006503R1 Power module: ABB brand new original, imported from Europe and America
USD $100 - $200 /Pound
Min.Order:100 Pounds
Xiamen xiongba e-commerce Co., Ltd. Zhangzhou Branch
PFSA140 3BSE006503R1 Power module: ABB brand new original, imported from Europe and America
PFSA140 3BSE006503R1 Power module: ABB brand new original, imported from Europe and America
Our Email: 2235954483@qq.com
contact number:13313705507
contacts:HE
Confirm whether the pulse sending mode matches the input pulse mode of the driver; Confirm whether there is hardware limit, software limit and ALM signal; The test software can be used to test and observe whether the pulse count is normal; The controller has been working normally, and it can be started normally
Pulse is generated, but the motor does not rotate.
Check whether the connection between the driver and the motor is correct and whether the wiring between the driver and the controller is in good contact.
Make sure that the drive works normally and there is no alarm. The motor can rotate but does not work properly
Often.
Check whether the set deceleration and speed exceed the equipment limit; Check whether the output pulse frequency exceeds the receiving limit of the driver; Check whether the controller and driver are properly grounded and whether anti-interference measures are well taken; The current limiting resistance used in the photoelectric isolation circuit of the pulse and direction signal output end is too large and the working current is too small.
Can control the motor, but the motor appears
Oscillation or overshoot.
It may be that the driver parameter setting is incorrect. Check the driver parameter setting; The acceleration / deceleration time and motion speed in the application software are not set properly. The motor can be controlled, but when working, the
The origin is not positioned correctly.
Whether the origin signal switch works normally;
Whether the origin signal is disturbed.
The limit signal does not work. The limit sensor does not work normally;
Limit sensor signal is disturbed;
The expansion module cannot be connected. The expansion module
The warning light is on.
Check whether the 120 ohm resistor is installed at both ends; Check whether there are multiple expansion modules with the same ID. If no signal is detected at the input port, check whether the IO power is supplied;
Check whether the signal level matches the input port. Check whether the input port number matches the ID of the IO board. There is no response during the operation of the output port. Check whether the IO power is supplied; The IO Board shall also be supplied with IO power. Check whether the output port number matches the ID of the IO board. Is the light of the controller network port not connected to the network port lit?
Is a direct network cable used and the computer does not support automatic crossing? Is the controller IP address modified?
Is the IP address of the network card of the PC the same network segment as the controller? The serial port of the controller is not connected. Is the serial port parameter modified by the running program and can be passed* Setcom view all current serial port configurations.