The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
MOOG D138-002-002
Perform PC8 corrective actions. PC10 HI.TEMP Temperature above transmitter range Verify process conditions are within transmitter range. Temperature must be within transmitter range. Verify process conditions are within configured output range. If temperature is outside configured range, increase range. Verify sensor wiring connections. Remove any liquids, oils, scales, or corrosion from transmitter terminal block or extension cable junction box terminals. Conduct temperature calibration. If not using temperature sensor, verify configuration for TMP.SNS is NONE and proper process temperature is set. Electronically test sensor and temperature compensator (PR25). Replace sensor if it does not meet requirements. PC11 LO.TEMP Temperature below transmitter range Perform PC10 corrective actions. PC12 HI.T.AD Open or missing temperature sensor Verify process conditions are within transmitter range. Temperature must be within transmitter range. Verify process conditions are within configured output range. If temperature is outside configured range, increase range. Verify sensor wiring connections. Remove any liquids, oils, scales, or corrosion from transmitter terminal block or extension cable junction box terminals. Conduct temperature calibration. If not using temperature sensor, verify configuration for TMP.SNS is NONE and proper process temperature is set. Electronically test sensor and temperature compensator (PR25). Replace sensor if it does not meet requirements. Replace 2-electrode conductivity input PCB assembly. PC13 LO.T.AD Shorted temperature sensor Perform PC12 corrective actions. Table 12-2. Uncommon Problem Codes Code Text String Description Corrective Action PC20 BAD.SEE Bad SEEPROM or 2-electrode conductivity input PCB assembly Input PCB factory calibration constants can not be loaded. Calibrate sensor and order replacement 2-electrode conductivity input PCB assembly. Existing assembly should properly function until new assembly is received. PC21 NO.F.CAL Missing factory calibration and functional SEEPROM Contact ABB for factory calibration procedure. Calibrate sensor for short-term usage until factory calibration is performed or a new 2-electrode conductivity input PCB assembly is installed. PC22 BLNK.uP Blank microprocessor EEPROM Cycle transmitter power.