Module spare part s  KOKUSAI CXP-544A KOMS-A2

Module spare part s KOKUSAI CXP-544A KOMS-A2

USD $1 - $10000000 /Piece

Min.Order:1 Piece

Supply Ability:
100 Piece / Pieces per Month
Port:
xiamen
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
Delivery Detail:
1 days

Quick Details View All >

Brand Name:
KOKUSAI
Place of Origin:
Austria
Model Number:
KOKUSAI CXP-544A KOMS-A2

Ruichang Mingsheng import and export trade Co., Ltd

Business license
Business Type: Trading Company
Main Products: ABB GE FOXBORO TRICONEX  BENTLY A-B EMERSON 

Product Details

Focus on DCS, PLC, robot control system and large servo system.

Main products: various modules / cards, controllers, touch screens, servo drivers.

Advantages: supply of imported original products, professional production parts,

Fast delivery, accurate delivery time,

The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands





KOKUSAI CXP-544A KOMS-A2










The transmitter has a utility mode of operation that provides access to powerful functions not usually needed during normal operating conditions. These functions have been separated into two categories: factory and user. Factory functions are reserved to ABB personnel. User functions include: programming mode selection, reset configuration to default values, remove security, reset all parameters to default values, and a software boot. There is only one procedure for the utility mode (PR23). It contains brief descriptions of each utility mode state. FACTORY AND USER STATES Access the factory and user states of operation by using the hidden fifth key located in the center top of the front panel. Once pressed, the hidden key causes the textual prompt USER to display in the secondary display region. Pressing the SELECT smart key moves the transmitter into the user state. Pressing the NEXT smart key moves the transmitter to the factory selection. Pressing the exit to MEASURE smart key escapes back to the measure mode. The user state consists of five states of operation. Table 11-1 describes the function of each state. The NEXT smart key sequentially moves through each of the five user states. This cycle repeats until a state is selected or the escape function is chosen using the exit to MEASURE Table 11-1. User States State Display Function Mode MODE Sets programming mode (basic or advanced) that can be selected in the modify configure mode of operation. Reset configuration RST.CON Resets configuration to factory defaults. Reset security RST.SEC Resets security to OFF state for all applicable modes and modify configure state. Reset all RST.ALL Resets all programming parameters such as configuration, calibration, output/hold, security, and secondary display functions to factory defaults. Soft boot RST.SFT Initiates software reset. UTILITY MODE FACTORY AND USER STATES 11 - 2 WTPEEUI520002A1 smart key. To select a state, press the SELECT smart key when the desired user state is shown in the secondary display region. Figure 11-1 identifies the smart key assignments and resulting action. Figure 11-1. User State Screen Flow T03442A MEASURE MODE MODE RETURN RSTCON RETURN RSTSEC RETURN R S TA LL RETURN USER RSTSFT RETURN RSTCON RSTSEC R S TA LL RSTSFT MEASURE C A LIB R ATE OUT/HOLD CONFIGURE SECURITY D ISPLAY MEASURE C A LIB R ATE OUT/HOLD CONFIGURE SECURITY D ISPLAY MEASURE C A LIB R ATE OUT/HOLD CONFIGURE SECURITY D ISPLAY MEASURE C ALIB R ATE OUT/HOLD CONFIGURE SECURITY D ISPLAY MEASURE C ALIB R ATE OUT/HOLD CONFIGURE SECURITY D ISPLAY exit to MEASURE exit to MEASURE exit to MEASURE exit to MEASURE exit to MEASURE MODE R S T.C O N R S T.S E C R S T.A LL R S T.S F T 6.82 6.82 6.82 6.82 6.82 SELECT SELECT SELECT SELECT SELECT NEXT NEXT NEXT NEXT NEXT mS/cm mS/cm mS/cm mS/cm mS/cm INTRODUCTION WTPEEUI520002A1 12 - 1 SECTION 12 - DIAGNOSTICS AND TROUBLESHOOTING INTRODUCTION The Type TB82TE transmitter performs a number of diagnostic checks on hardware, software, and sensor functions. Upon detection of a nonconforming condition, the FAULT icon locally alerts the operator. Configurable remote indication is performed by using the spike output option to modulate the output current. Pressing the FAULT info smart key interrogates the transmitter as to the cause of the fault. The display of a short text string and fault code alternate on the secondary display. If multiple faults exist, pressing the FAULT info smart key moves the display to the next fault. Upon interrogation of all faults, the transmitter returns to the measure mode and the MENU smart key icon appears. This section describes the type of fault conditions and their applicability to transmitter functionality. If the evaluation of the fault codes does not resolve the problem, refer to TROUBLESHOOTING SEQUENCE to find additional troubleshooting procedures. FAULT CODES Fault conditions are grouped into two categories based on their severity. Conditions that result in degradation of transmitter performance are reported as problem codes (PC). Conditions that render the transmitter inoperable are reported as error codes (EC). Fault codes are reported in the secondary display region in a first in, first out (FIFO) order. All active fault conditions can be viewed at any time while in the measure mode by using the FAULT info smart key. A flashing FAULT icon indicates a new fault condition that has not been interrogated. Upon resolution of all fault conditions, the FAULT icon and FAULT info smart key disappear. Problem Codes Problem codes result from fault conditions that impact the performance of the transmitter. These conditions are usually resolved using standard practices. The occurrence of a problem code fault condition energizes the FAULT icon and modulates the spike output (if configured). These diagnostic indicators p

Contact Supplier

Ms. Chat Now

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Other Electrical Equipment
Categories
Hi~