DC532 1SAP240100R0001 ABB PLC module spot inquiry
USD $100 - $200 /Pound
Min.Order:100 Pounds
Xiamen xiongba e-commerce Co., Ltd. Zhangzhou Branch
DC532 1SAP240100R0001 ABB PLC module spot inquiry
DC532 1SAP240100R0001 ABB PLC module spot inquiry
• 45 through 3000 kVA • 65° C average winding rise • 60 hertz standard, 50 hertz optional 45-1500 kVA • High voltages: 4160 Grd Y/2400 through 34,500 Grd Y/19,920 for Grounded Wye systems; 2400 through 34,500 for Delta systems; various dual high voltages 2000-3000 kVA • High voltages: 7200 Grd Y/4160 through 34,500 Grd Y/19,920 for Grounded Wye systems; 4160 through 34,500 for Delta systems; various dual high voltages • Taps: All voltages are available with or without taps • Insulation classes: 35 kV, 150 kV BIL and below 45-1500 kVA • Low voltages: 208Y/120, 216Y/125, 460Y/265, 480Y/277, 480∆, 240∆ and 240∆ with 120 volt mid-tap in one phase; (4160Y/2400, 4160∆, 2400∆ , 2400/4160Y/2400 for 500 kVA and larger) 2000-3000 kVA • Low voltages: 460Y/265, 480Y/277, 480∆, 4160Y/2400, 2400∆, 2400/4160Y/2400
Our Email: 2235954483@qq.com
contact number:13313705507
contacts:HE
The following are the main brands:
1. {Rockwell Allen Bradley}
2.ABB
3. {Schneider}
4. {General Electric}
5. {Honeywell}
6. {Westinghouse}
7. Hima {black horse}
8. Kollmorgen {kolmorgan}
9. Reliance {Ryan}
10. {Woodward}
11. {Bosch Rexroth}
12. B & R
13.KUKA
14. {foxoboro}
15. Emerson {Emerson}
16.XYCOM
17. FANUC {FANUC}
wait......
Standard Features: 1. Four lifting lugs. 2. Bolted-on terminal compartment (18" or 24" deep depending on KVA) with removable front sill. 3. Hinged, lift-off cabinet doors. 4. Interlocked penta-head bolt/padlock handle operates a cam assembly which is part of the 3-point door latching mechanism. (A hex-head bolt is available.) 5. For live front construction, externally clamped high voltage porcelain bushings with a single eyebolt, clamp-type connector (accommodates #6 AWG solid to 250 MCM stranded conductors). 6. For dead front construction, externally clamped high voltage bushing wells for loadbreak or non-loadbreak inserts. 7. Lightning arrester mounting pads (live front only). 8. Tank ground pads (1 in HV, 1 in LV). 9. Steel high/low voltage compartment barrier. 10. One 1/2" penta-head bolt must be removed from the flange formed on the steel high/low barrier before the HV door can be opened (1/2" hex-head bolt available as an option). 11. Externally clamped low voltage bushings with threaded copper stud for full load current below 2100 amps. Externally clamped integral low voltage bushings for current above 2100 amps. NEMA spades provided per ANSI hole requirements. 12. Nameplate. 13. Fill plug and self-actuating pressure relief device. 14. Drain plug. 15. Removable neutral ground strap. 16. Five-legged core/coil assembly. 17. Handhole cover bolted onto tank top (protected by weathercover). 18. Panel-type coolers. 19. NEMA safety labels. 20. The paint finish process applies a durable, corrosion resistant finish to the product. The multi-step process includes an epoxy primer uniformly applied by cationic electrodeposition and a urethane top coat.