R88M-GP10030T-Z AC Servomotor With ABS/INC OMRON Encoder Flat-Style 100W 200 VAC Without Key / Without Brake 3000rpm
3,000-r/min Flat Servomotors
Model (R88M-) | 100 VAC | 200 VAC |
---|
GP10030L | GP20030L | GP40030L | GP10030H | GP20030H | GP40030H |
---|
Item | Unit | GP10030S | GP20030S | GP40030S | GP10030T | GP20030T | GP40030T |
---|
Rated output *1 | W | 100 | 200 | 400 | 100 | 200 | 400 |
---|
Rated torque *1 | N·m | 0.32 | 0.64 | 1.3 | 0.32 | 0.64 | 1.3 |
---|
Rated rotation speed | r/min | 3000 |
---|
Max. momentary rotation speed | r/min | 5000 | 4500 | 5000 |
---|
Max. momentary torque *1 | N·m | 0.84 | 1.8 | 3.6 | 0.86 | 1.8 | 3.65 |
---|
Rated current *1 | A (rms) | 1.6 | 2.5 | 4.4 | 1 | 1.6 | 2.5 |
---|
Max. momentary current *1 | A (rms) | 4.9 | 7.5 | 13.3 | 3.1 | 4.9 | 7.5 |
---|
Rotor inertia | kg·m2 (GD2/4) | 1.0 × 10-5 | 3.5 × 10-5 | 6.5 × 10-5 | 1.0 × 10-5 | 3.5 × 10-5 | 6.4 × 10-5 |
---|
Applicable load inertia | --- | 20 times the rotor inertia max. *2 |
---|
Torque constant *1 | N·m/A | 0.21 | 0.27 | 0.3 | 0.34 | 0.42 | 0.54 |
---|
Power rate *1 | kW/s | 10.2 | 11.7 | 26.0 | 10.2 | 11.5 | 25.5 |
---|
Mechanical time constant | ms | 0.87 | 0.75 | 0.55 | 1.05 | 0.81 | 0.59 |
---|
Electrical time constant | ms | 3.4 | 6.7 | 6.7 | 2.9 | 5.6 | 6.6 |
---|
Allowable radial load *3 | N | 68 | 245 | 245 | 68 | 245 | 245 |
---|
Allowable thrust load *3 | N | 58 | 98 | 98 | 58 | 98 | 98 |
---|
Weight | Without brake | kg | Approx. 0.7 | Approx. 1.3 | Approx. 1.8 | Approx. 0.7 | Approx. 1.3 | Approx. 1.8 |
---|
With brake | kg | Approx. 0.9 | Approx. 2 | Approx. 2.5 | Approx. 0.9 | Approx. 2 | Approx. 2.5 |
---|
Radiation shield dimensions (material) | 130 × 120 × t10 (AI) | 170 × 160 × t12 (AI) | 130 × 120 × t10 (AI) | 170 × 160 × t12 (AI) |
---|
Applicable Servo Drives (R88D-) | GT01L | GT02L | GT04L | GT01H | GT02H | GT04H |
---|
Brake spec- ifica- tions | Brake inertia | kg·m2 (GD2/4) | 3 × 10-6 | 9 × 10-6 | 3 × 10-6 | 9 × 10-6 |
---|
Excitation voltage *4 | V | 24 VDC ± 10% |
---|
Power consumption (at 20 °C) | W | 7 | 10 | 7 | 10 |
---|
Current consumption (at 20 °C) | A | 0.29 | 0.41 | 0.29 | 0.41 |
---|
Static friction torque | N·m | 0.29 min. | 0.29 min. | 1.27 min. |
---|
Attraction time *5 | ms | 50 max. | 50 max. | 60 max. |
---|
Release time *5 | ms | 15 max. |
---|
Backlash |
| ± 1 ° |
---|
Allowable work per braking | J | 137 | 196 | 137 | 196 |
---|
Allowable total work | J | 44.1 × 103 | 147 × 103 | 44.1 × 103 | 147 × 103 |
---|
Allowable angular acceleration | rad/s2 | 10,000 max. (Speed of 900 r/min or more must not be changed in less than 10 ms) |
---|
Brake life | --- | 10,000,000 operations min. |
---|
Rating | --- | Continuous | Continuous |
---|
Insulation grade | --- | Type F |
---|
*1. These are the values when the Servomotor is combined with a Servo Drive at room temperature (20°C, 65%). The
maximum momentary torque shown above indicates the standard value.
*2. Applicable Load Inertia:
• The operable load inertia ratio (load inertia/rotor inertia) depends on the mechanical configuration and its rigidity.
For a machine with high rigidity, operation is possible even with high load inertia. Select an appropriate motor and
confirm that operation is possible.
• If the dynamic brake is activated frequently with high load inertia, the dynamic brake resistor may burn. Do not
repeatedly turn the Servomotor ON and OFF while the dynamic brake is enabled.
• The dynamic brake is designed only for emergency stops. Design the system so that the Servomotor remains
stopped for at least 3 minutes after applying the dynamic brake. Otherwise the dynamic brake circuits may fail.
*3. The allowable radial and thrust loads are the values determined for a service life of 20,000 hours at normal operating
temperatures. The allowable radial loads are applied as shown in the following diagram.
*4. This is an OFF brake. (It is reset when excitation voltage is applied).
*5. The operation time is the value (reference value) measured with a surge suppressor (CR50500 manufactured by
Okaya Electric Industries Co., Ltd.).
A variety of axial-flow fans that achieve optimal cooling.
The design with low noise, high service life and good environmental adaptability is considered. Ball bearing with high reliability is adopted.
It has a resin blade specification 48 type and a metal blade specification 24 type.
The user manual of waterproof AC axial flow fan r87f-a-a16h-wr (protection structure IP65) r88m-gp10030t-z is also added.
There are also many models that have passed the safety standards ulcsavde and en / IEC certification r88m-gp10030t-zr87f-a a83ac axial flow fan (80xt25, wire type). Rated voltage: 230V.
Allowable voltage variation range: 85 ~ 110% of rated voltage. Frequency: 50 / 60Hz
Rated current: 50Hz -- 0.038a; 60Hz--0.034A. Rated input: 50Hz -- 7W; 60Hz--6W.
Rated speed: 50Hz -- 2600r / min: 60Hz -- 3000r / min r88m-gp10030t-z user manual. Maximum air volume: 50Hz -- 0.57m3/min; 60Hz--0.67m3/min. Maximum static pressure: 50Hz -- 39.2pa; 60Hz--53.0Pa. Noise: 50Hz -- 34dB: 60Hz -- 38dB
A variety of axial-flow fans that achieve optimal cooling.
Considering the design of low noise, high life and good environmental adaptability. Ball bearing with high reliability is adopted.
It has a resin blade specification 48 type and a metal blade specification 24 type.
Waterproof AC axial flow fan r87f-a-a16h-wr (protection structure IP65) is also added.
There are also many models that have passed the safety standards UL, CSA, VDE and en / IEC certification.
Category: metal blade axial flow fan.
Power supply voltage: ac21 connected, 2 connected and 3 connected r88m-gp10030t-z user manual. The mounting hole is a square hole, which hides the structure of the hole processing surface and is easy to process. The upper and lower switch covers can be selected (convenient for use in narrow places).
Accessories (finger protection, filter, socket cover, mounting screws) are enriched. As an option, it is equipped with accessories for replacing filters and air suction and exhaust ports. There are 8 types of resin blades and 8 types of metal blades
From company 1 to company 3, there are complete varieties. R87f-a a16h-wr waterproof AC axial flow fan (120xt40, wire type). Rated voltage: 200V.
Allowable voltage variation range: 85 ~ 110% of rated voltage. Frequency: 50 / 60Hz
Rated current: 50Hz -- 0.109a; 60Hz--0.098A. Rated input: 50Hz -- 16W: 60Hz -- 15W
Rated speed: 50Hz -- 2690r / min; 60Hz -- 3040r / min maximum air volume: 50Hz -- 2.3m3/min; 60Hz -- 2.5m3/min maximum static pressure: 50Hz -- 70.9pa; 60Hz -- 69.6pa noise: 50Hz -- 43db: 60Hz -- 46db
A variety of axial-flow fans that achieve optimal cooling.
Consider the design r88m-gp10030t-z manual with low noise, high life and good environmental adaptability. The bearing adopts the r88m-gp10030t-z Manual of lacquer bead bearing with high reliability. It has a resin blade specification 48 type and a metal blade specification 24 type.
Waterproof AC axial flow fan r87f-a-a16h-wr (protection structure IP65) is also added.
There are also many models that have passed the safety standards UL, CSA, VDE and en / IEC certification.