BNAAS-A3081G High Quality and Cheap Price AAS Atomic Absorption Spectrophotometer
Negotiable
Min.Order:1
BNAAS-A3081G High Quality AAS Atomic Absorption Spectrophotometer
Optical system |
|
Wavelength range |
190nm-900nm |
Monochromator |
C-T type of eliminating aberration monochromator |
Dispersion elements |
Plane diffraction grating,1800 lines/mm,indented area(40×40)mm2 |
Spectral bandwidth |
0.1nm, 0.2nm, 0.4nm, 1.0nm, 2.0nm for option |
Wavelength precision |
The whole waveband is better than ±0.15nm |
Wavelength repeatability |
The whole waveband is <0.10nm |
Resolution |
Copper lamp 324.7nm0.2nm and bandwidth deviation within ±0.015nm |
Baseline drift |
0.004A/30min |
Element lamp holders |
Four lamps can auto-switch without manual-adjustment |
Detectors |
High sensitivity, wide spectral range photomultiplier tube |
Flame Atomization System (FAS) |
|
Concentration(Cu) |
0.02ug/ml/1% |
LOQ (Cu) |
0.006ug/ml |
Burner |
100mm, single-slit titanium metal burner, which is air-cooled pre-mixed type |
Precision |
RSD≤0.8% |
Sprayer |
High efficiency glass sprayer |
Atomization chamber |
Corrosion-resistant plastic atomization chamber |
Position adjustment |
The auto-setting of flame burner height and position |
Safety measures |
Various of automatic safety protection function |
Graphite Atomization System (GAS) |
|
Characteristic statistic(Cd) |
0.5×10-12g |
LOQ (Cd) |
1.0×10-12g |
Precision |
RSD≤1.5% |
Heating range |
Room temperature~3000℃ |
Heating operation methods |
Power control method for dry ashing stage, max power light control for atomization stage |
Temperature control precision |
≤1% |
Heating rate |
>2000℃/sec. |
Heating condition setting |
Up to 11 programs, ramp heating , stage heating and max power heating |
Safety protection |
Functions of argon undervoltage instruction, waterflow discharge cooling, overheating or overflow alarm and auto-protection. |
Background Subtraction |
|
Back subtraction of deuterium lamp |
1Ahour≥50times |
Data processing |
|
Measuring method |
Air-acetylene flame method and atomic absorption method for hydride generator |
Concentration calculate method |
Standard curve method(1~3 times curve), standard mixing method |
Repeat measuring times |
1~20 times,repeatedly measure and calculate the average data and automatically get the standard deviation and relative deviation. |
Result printed |
Parameter printed, data results printed and exported to Excel, graphics printed and summary report. |