Characteristics:

1.High accuracy of temperature control (optimum: ± 0.05°C), high reliability and anti-interference.

2.Control and operating parameters (including for detectors) set up by the keyboard. Self-diagnosis system, power-fail protection, file storage and call, limited temperature setting. Accurate display of setting and actual value of temperature control of each path, bridge current of TCD, sensitivity of FID, retention and analysis time.

3.Four paths of independent control sections: column oven, sample injector, detector and thermal conductive pond.

4.5-ramp programmed temperature rising control. Auto-drop of temperature of column oven (auto-opening the door behind the oven) to a fast cooling.

5.Dual FID provided with options of GC112 A-TCD, GC 112 A-FPD and GC112A-NPD, gas sampling valve, transformation oven, absorber and pyrolysis absorber available for selection. Two detectors can be installed at the same time with high sensitivity. Short time to be stabilized and easy to clean and install nozzle.

6.Packed column and capillary column (0.53 large diameter or small diameter) can be installed easily including a complete set of split sampling connector and tailing connector to be installed free of charge.

7.Analysis can be conducted in packed or capillary column with multiple sampling methods.

8.Packed column: on-column sampling, instantaneous vaporized sampling and gas sampling.

9.Capillary column: split sampling and 0.53mm large diameter capillary direct sampling.

10.Construction of dual gas path, dual sample injector and dual packed column system can effectively avoid baseline undulation and drift in real time and facilitate programmed temperature rising analysis. Accurate and scaled type gas path control valves will provide a high repeatability and stability.

11.Advanced functions: auto ON/OFF temperature control system, permanent data storage, file storage and call and over-temperature protection.

12.Large volume column (300x280x270) can hold capillary column and dual packed column. Built-in heating filament structure is in favor of quartz capillary analysis.

13.A complete set of accessories including purifier, pressure-reducing valve, gas path tube, wrench and tools, injection needle and connectors of all kinds are provided free of charge and are ready to connect with supply-air system prepared by users.

Technical Data:

· Temperature control

Control range

above room temperature 7°C - 400°C. (increment of 1°C)

Control objects

column oven, detector, thermal conductive pond and sample injector

Programmed temperature rising

5 ramps

Rate of programmed temperature rising

0.1°C -40°C/min (increment of 0.1°C)

Thermostatic time

0-655 min (increment of 1 min)

· FID

Sensitivity (minimum testability)

D£5´10-11 g/s (sample: C16)

Optimum testing result

D£1´10-11 g/s

Noise

£5´10-14 A

Drift

£6´10-13 A/h

Linear range

³106

· TCD

Sensitivity

³2000mV.ml/mg

Noise

£20mV

Drift

£30mV

Linear range

³104

· FPD

Sensitivity (minimum testability)

£2´10-11 g (P)/s (sample P in the parathion methyl)

 

Optimum testing result: £3.8´10-12 g (P)/s.

Sensitivity (minimum testability)

£1´10-10 g (S)/s (sample: S in the parathion methyl)

 

Optimum testing result: £2.7´10-11 g (S)/s

Linear range

³103 (sample P parathion)

 

³102 (sample S parathion)

Stability

£30mV/h

Noise

£10mV

Starting time

not greater than 2 hours

· NPD

Sensitivity (minimum testability)

Dt(N)£5pg (N)/s

Optimum testing result: 0.5ppm

 

Sensitivity (minimum testability)

Dt(P) £0.5pg (P)/s

Optimum testing result: 0.2ppm

 

Drift

£8´10-13 A/h

Noise

£4´10-13 A

Linear range

³103

Max application temperature

360°C

Optional accessories:

1. TCD

2. FPD

3. NPD

4. CDP-4A data processor

5. Software with I/O port

Overall dimension & weight:

Shipping package dimension:   990-630-690mm

Net Weight:    50kg

Gross Weight:  75kg

                                                                                                                                               Please send inquiry>>

GC112A high performance gas chromatograph with low noise for sale

GC112A high performance gas chromatograph with low noise for sale

GC112A high performance gas chromatograph with low noise for sale

GC112A high performance gas chromatograph with low noise for sale

GC112A high performance gas chromatograph with low noise for sale

                                       If you need any detail packing information, please contact us>>

GC112A high performance gas chromatograph with low noise for sale

                                                                       If you have any question, please contact us>>

GC112A high performance gas chromatograph with low noise for sale

GC112A high performance gas chromatograph with low noise for sale

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Analyzers > Gas Analyzers
Categories
Hi~