Product Details

AA320N high quality flame atomic absorption spectrophotometer

Product Features

AA320N high quality flame atomic absorption spectrophotometer

AA320N high quality flame atomic absorption spectrophotometer 

Characteristics:

1.Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium lamp background correction, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.

2.Stability: Double-beam system can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.

3.Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.

4.High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration

5.High energy optical path: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced.

6.Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.

7.Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.

8.Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetylene flame as well as nitrous oxide-acetylene flame and extend the analytic elements to reach more than 60.

9.Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased

Technical data:

WL range (nm)    

190-900

WL accuracy

£ ±0.5nm

WL repeatability

£ 0.3nm (single direction)

Spectrum bandwidth

0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm

Resolution

<40%

Base line stability

±0.004Abs/30min

Characteristic concentration of copper

£ 0.04mg/ml/1%

Detection limit of copper

£0.008mg/ml

Background calibration ability

Greater than 30 times

RS232

including

Printer

optional

Power supply

220V 3A, 50Hz

Package Dimensions

1220x770x730mm (Main instrument)

800x400x900mm  ( Accessories )

 

Standard Accessories:

Oil-free air compressor

EPSON Printer

Glass Atomizer

Cu Hollow cathode lamp

Atomizer unit

Burner unit

Dust cover

Water-separating gas filter

Titanium burner---10cm

Optional Accessories:

Model GA3202 HGA graphite furnace system-

Titanium burner---5cm

Nitrous oxide generator

Hydride generator

Graphite tubes

Acetylene Regulator YQE-213

Nitrous oxide regulator

Software

  recirculating cooling water system

 

 

 

Model GA3202 HGA graphite furnace system

1. Heating steps: 9 steps

2. Temperature range (nominal Temperature): 20·c-3000'C

3. Slope heating time: 0-999s

4. Heating holding time: 1 s-999s (the sum of both time should be less than 999 seconds)

5. Inert gas needed: argon, pressure of entry larger than 0.3Mpa

6. Cooling water: tap water or cycling water, flow rate no less than 2L/min

7. Output: LCD

8. Gas pressure alarm, furnace overheated alarm

9. Interface with Atomic absorption spectrophotometer, autosampler and RS232

10. High-power temperature heating function (1000℃-2700℃)

11. Test sample together with atom absorption equipment. Cd ≤1x10-12g; Cu ≤1x10-10g

12.  Working Conditions: 

Power source: 220V±22V,50Hz±1Hz,3A

                       220V±22V,50Hz±1Hz,30A

Power: 5.1 kW for 220V on about 2700℃

Ambient temperature: +10℃~+30℃

Relative humidity: less than 85%

Instrument rating power: 7.2kW

                                                                                                                                                                   Please send inquiry>>

AA320N high quality flame atomic absorption spectrophotometer

AA320N high quality flame atomic absorption spectrophotometer

AA320N high quality flame atomic absorption spectrophotometer

AA320N high quality flame atomic absorption spectrophotometer

AA320N high quality flame atomic absorption spectrophotometer

                                       If you need any detail packing information, please contact us>>

AA320N high quality flame atomic absorption spectrophotometer

                                                                       If you have any question, please contact us>>

AA320N high quality flame atomic absorption spectrophotometer

AA320N high quality flame atomic absorption spectrophotometer

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now