Lab use aa320n flame atomic absorption spectrophotometer manufacturers

Our Product

•Feature and Description

1).Characteristics A
1.Build-in computer data processing and LCD: adopting highly integrated micro digital circuit, which 
is

stable and reliable with the functions of integral holding, peak height and area, auto zero adjusting, deuterium

lamp and background, multi-linear and nonlinear curves fitting, various parameters and working curves displayed

in screen and report printing, etc. It is equipped with interface for externally linking PC.


2.Good basic line stability: Double-beam system of optimized design can automatically compensate 
the light source

drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection

of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.

The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable

instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.

 

3. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and

current Stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes

through the flame to ensure a high precision analytical test and low characteristic concentration


4. Optical path of high energy: A total reflection system is adopted to eliminate color difference in full range.

By means of chemical conversion, a round light spot of the light source becomes a long light spot, which

enters into the slit.Therefore the light flux of double beam is enhanced.


5. Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys,

anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-

cooling.


6. Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic
absorption and hydride generation.


7. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be

used to analyze air-acetylene flame .


8.Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.

 

2).Characteristics B
1 Light-source system: Hollow cathode lamp power supply: with adjustable current Deuterium Lamp power supply:

with fixed current


2 Optical system: Double beam total refection system, C-T type monochromator Flashing wavelength: 250nm


3 Flame atomization system: Inter-changeable titanium alloy burner of 10cm and 5cm slits. Gas path is equipped with
pressure indication, high precision voltage stabilizing flow adjustment, fast conversion of air and nitrous oxide, gas
supply cut off, power cut off, prevention of flashback and logic interlock protection devices.


4 Signal processing: absorptance, concentration, emission and emission concentration; Standard curves: linear
regression, curve fitting and multi-point standard calibration. Average value, standard deviation, relative standard
deviation and correlation coefficient can be worked out. Standard curves, atomic absorption peak diagram, spectrum
outline sketch, data as well as instrument parameters list and analytical reports can be displayed and printed out.

 

•Picture for Our product:

Lab use AA320N flame atomic absorption spectrophotometer manufacturersLab use AA320N flame atomic absorption spectrophotometer manufacturersLab use AA320N flame atomic absorption spectrophotometer manufacturersLab use AA320N flame atomic absorption spectrophotometer manufacturersLab use AA320N flame atomic absorption spectrophotometer manufacturersLab use AA320N flame atomic absorption spectrophotometer manufacturersLab use AA320N flame atomic absorption spectrophotometer manufacturers

 

 

 

 

•Technical data

Wavelength accuracy: ≤ ±0.5nm
Wavelength repeatability: ≤ 0.3nm (single direction)
Spectrum bandwidth: 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Resolution: <40%
Base line stability: ±0.004Abs/30min
Characteristic concentration of copper: ≤ 0.04mg/ml/1%
Detection limit of copper: ≤0.008mg/ml
Background calibration ability: Greater than 30 times.
Standby Interface: RS 232
Instrument power supply: 220V, 3A, 50Hz

•Packing and Shipping

Lab use AA320N flame atomic absorption spectrophotometer manufacturers

•Related Product

Hollow cathode lamp Graphite furnace
Lab use AA320N flame atomic absorption spectrophotometer manufacturers Lab use AA320N flame atomic absorption spectrophotometer manufacturers
Our Copmany

1.Company Show

Lab use AA320N flame atomic absorption spectrophotometer manufacturers

2.Factory Show

 

Our Services

Certificate

Lab use AA320N flame atomic absorption spectrophotometer manufacturers

After-Sale Service

Lab use AA320N flame atomic absorption spectrophotometer manufacturers 

Contact Us

Lab use AA320N flame atomic absorption spectrophotometer manufacturers 

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Optical Instruments > Spectrometers
Categories
Hi~