MSMA022A1E AC Panasonic 0.2kw Rated Output Servo Motor Controller
USD $1 - $1000000 /Unit
Min.Order:1 Unit
Huizhou Linchuang Technology Co ., Ltd
MSMA022C1N Panasonic Servo AC Industrial Machine 400W Power Supply
MSMA022A1C Panasonic Industrial MSMA Series Motor 0.8kg Gross Weight
HF-KP73BG1 Servo Mitsubishi 8.2kg Weight AC Brushless Servo Motor
HF-KP43-S21 Mitsubishi Servo HF-KP Series Motors 400W Output Moudel
HG-KN13BJ-S100 Mitsubishi Medium Power Electronic Brushless Motor
HG-KN43BJ-S100 Mitsubishi Module Medium Inertia 0.4kw Servo Motor
Panasonic original package servo motor MSMA022A1E new Make in Japan
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC - |
Fanuc motor A0- | Yokogawa transmitter EJA- |
Voltage The voltage at which the motor is designed to operate is an important parameter. Standard voltage for motors built to NEMA MG 1 (1987) are defined in MG 1-10.30. One common misapplication is of motors nameplated (rated) at one voltage but applied on a different voltage network using the + 10% voltage tolerance for "successful" operation. Nameplate-defined parameters for the motor such as power factor, efficiency, torque, and current are at rated voltage and frequency. Application at other than nameplate voltage will likely produce different performance. It is common for manufacturers to nameplate a wide variety of voltages on one motor nameplate. A common example is a motor wound for 230 and 460 V (230/460 V) but operable on 208 V. This 208-230/460 V motor will have degraded performance at 208 V. Another common misconception is to request a motor rated at network voltage; for example, at 480 V. The NEMA standard is 460 V.
The voltage rating assumes that there is voltage drop from the network to the motor terminals. Thus, the 460-V motor is appropriate on a 480-V network. Frequency Input frequency is usually 50 or 60 Hz. When more than one frequency is nameplated, other parameters that will differ at different input frequencies must be defined on the nameplate. The increasing use of adjustable frequency drives (AFDs) is also making it necessary to nameplate a frequency range, especially for hazardous-duty-listed applications. Phase This represents the number of ac power lines supplying the motor. Single and three-phase are the norms. Current Rated load current in amps is at nameplate horsepower (HP) with nameplate voltage and frequency. When using current measurement to determine motor load, it is important that correction be made for the operating power factor. Unbalanced phases, undervoltage conditions, or both, cause current to deviate from nameplate AMPS. Review both motor and drive for a matched system regarding current on AFD applications. Code A letter code defines the locked rotor kVA on a per-hp basis. Codes are defined in MG 1-10.37.2 by a series of letters from A to V. Generally, the farther the code letter from A, the higher the inrush current per hp. A replacement motor with a "higher" code may require different upstream electrical equipment, such as motor starters.
Type NEMA MG 1 requires manufacturer's type, but there is no industry standard regarding what this is. Some manufacturers use "Type" to define the motor as single or polyphase, single or multispeed, or even by type of construction. Type is of little use in defining a motor for replacement purposes unless you also note the specific motor manufacturer. Power factor Also given on the nameplate as "P.F." or PF," power factor is the ratio of the active power (W) to the apparent power (VA) expressed as a percentage. It is numerically equal to the cosine of the angle of lag of the input current with respect to its voltage, multiplied by 100. For an induction motor, power factor also varies with load. The nameplate provides the power factor for the motor at full load.