Feature

  • 3 part differential hematology analyzer, 20 parameters & 3 histogram (WBC, RBC, PLT)
  • Fully automatic analysis cycle
  • Automatic internal and external probe cleaning
  • High Reliability and Safety
  • Huge storage of 15,000 patient results with histogram
  • Easy touch screen operation.
  • Support external Laser Printer, Programmable multiple format printout

Technical Specification

 

 

Principle

Electrical resistance for counting, hemoglobincyanide method and SFT method for hemoglobin

Parameters

3-part differential of WBC, 20 parameters+3 color histograms (WBC/RBC/PLT). 20 parameters: WBC, LYM%, MID%, NEUT%, LYM#, MID#, NEUT#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV,  PLT,  MPV,  PDW,  PCT,  P-LCR

Sample Volume

Venous Mode: 9.6uL, Capillary Mode: 9.6uL, Pre-diluted: 20uL

Working Mode

Counting passages detection+independent HGB measurement system, 24 hours with auto standby

Operation Mode

Touch screen operation, keyboard and mouse operation

Throughput

60 samples per hour

Data Storage

Up to 15,000 results inclusive of the histograms

QC mode

L-J, X, X-B, SD, CV, QC histograms

Calibration Mode

Relatively independent manual calibration and auto calibration in 3 detecting modes

Cross Contamination Ratio

WBC, RBC, HGB<0.5%, PLT<1%

Performance

Parameter Repeat-ability

Linear Range

WBC≤2.5%

0.00-99.9×108 /L

RBC≤2.0%

0.00-9.99×1012/L

HGB≤1.5%

0-300.0 g/L

MCV≤0.4%

40-150fL

PLT≤5.0%(100-500)

0-999×109/L

Display

8.4 inch LCD, resolution 640×480

Reference value

Baby, Kid, women, man, normal and customization

Interface

2×USB, 1×parallel (for external printer), 1×VGA (for external monitor), RS232(for network)

Printout

Built-in thermal recorder, optional external printer, 8 report format

Working Environment

Temperature: 15-35℃, Humidity:10-90%

Power Requirement

AC100-240V 50/60Hz

 

 

 

 

 

 

 

 

 

 

 

 