CI627 CI627A ABB Inventory of industrial control spare parts
USD $100 - $200 /Pound
Min.Order:1 Pound
Xiamen xiongba e-commerce Co., Ltd. Zhangzhou Branch
CI627 CI627A ABB Inventory of industrial control spare parts
CI627 CI627A ABB Inventory of industrial control spare parts
3BSE 000 506R0001 The first release for MasterPiece 90 / MasterBus 90.
3BSE 000 506R0101 New name and layout, Advant Fieldbus 100 User’s Guide.
3BSE 000 506R0201 Includes information about S800 I/O.
3BSE 000 506R0301 Includes information about TC514, TC515, and CI627.
3BSE 000 506R0401 Includes information about interfaces for full redundant
media communication.
3BSE 000 506R0501 Includes information about communication interface
redundancy with CI522 bus coupler module and modem
TC516 for twisted pair media.
3BSE 000 506R0601 Includes information about redundant FCI for S800 I/O.
3BSE 000 506R701 Includes information about the possibility to use AF 100
over distances greater than 2000 meters (6500 ft.) in
CI522, CI810 and CI820.
3BSE 000 506R801 Includes CI527 and updates.
3BSE 000 506-510 Uses ABB template for AC 800M.
Includes AC 800M and CI869 updates.
3BSE 000 506-600 Includes minor updates
Our Email: 2235954483@qq.com
contact number:13313705507
contacts:HE
Advant Fieldbus 100 (AF 100) is a high performance fieldbus, which is used for: • Communication between Advant Controllers • Communication between Advant Controllers and S800 I/O Stations, AC 800M controllers, AC 100 OPC Server, and the equipments developed and sold by other ABB companies. In an AF 100 bus, it is possible to reach up to 80 stations within a total physical distance of up to 13300 meters (43300 feet). Advant Fieldbus supports three transmission media: • Twisted pair (Twp) • Coaxial (RG59 and RG11) • Optical media. An AF 100 bus can be built up with all the three media, where a part of one kind of media is a specific segment. The following rules apply to the segments: • To each twisted pair segment, 32 stations can be connected, and the maximum segment length is 750 meters (2500 feet) • The coaxial segment can be: – 300 meters (1000 feet) with cable RG59 or – 700 meters (2300 feet) with cable RG11. • The optical media is only used in point-to-point communication, and it allows the total length of a bus segment to be up to 1700 meters (5500 feet). • If back-to-back coupled optical segments are used, it is possible to reach up to a physical length of 13300 meters (43300 feet).
Communication Interfaces There are several communication components that can communicate on the Advant Fieldbus 100. The communication interfaces that have the capability to be Bus Administrators are CI520, CI522, CI525, CI526, CI527, CI626, CI627, CI630, and CI631. Advant Controller 70 The Advant Controller 70 has integrated Twisted Pair Modems for connection to Advant Fieldbus 100. Advant Controller 110 The Advant Controller 110 is connected to the Advant Fieldbus 100 via a CI626 communication interface for coaxial media or a CI627 communication interface for twisted pair media. Advant Controller 160 The Advant Controller 160 is connected to the Advant Fieldbus 100 via a CI626 or CI630 communication interface for coaxial media or a CI627 or CI631communication interface for twisted pair media. Advant Controller 400 Series The Advant Controller 400 Series is connected to the Advant Fieldbus 100 via single CI520 or via single or redundant CI522 communication interface, and modem TC625 for coaxial media or modem TC512/TC516 for twisted pair media. AC 800M The AC 800M controller is connected to the Advant Fieldbus 100 through single or redundant CI869 communication interfaces. The CI869 has integrated twisted pair modems.