TIANLONG PANA9600S nucleic acid equipment workstation fully automated automatic nucleic acid extraction system
USD $80000 - $100000 /Unit
Min.Order:1 Unit
Xi'an Tianlong Science & Technology Co., Ltd.
Product Information
Item | Value |
Product Model | PANA9600S |
Authoritative Certifications | NMPA, CE, etc. |
Sample Throughput | 1-96 |
Features | Automatic scanning and identification of sample information + nucleic acid extraction + PCR system setup |
Principle | The principle of magnetic bead method, and the technology of rotational mixing |
Detectability | 192 assays can be completed per run, with 4 different systems of PCR-setup simultaneously. |
Specimen Types | Samples of plasma, serum, whole blood, swab solution, and urine, etc. |
Sample Loading Channels | 1-4 |
Pipetting Performance | 15μL and below: accuracy: A≤2%, repetitive CV ≤ 3.0%; 15-50μL: accuracy: A≤1.5%, repetitive CV≤1.5%; 50μL and above: accuracy: A≤1.0%, repetitive CV≤1.2%; |
Liquid Level Detection | Capacitive-sensing level detection; pressure-sensing level detection |
Sample Tube Specifications | Compatible with a wide range of sample collection tubes, 1.5mL and 2.0mL centrifuge tubes, cryopreservation tubes and sample cups. |
Extraction Temperature Control Module | 2 steps: pyrolysis & elution, with temperature control from 35 to 120 °C. |
Visual Inspection Technology | Real-time inventory status monitoring of consumables and reagents |
PCR Reagent Chamber | Light-proofing design; automatic cooling on start-up (4 ℃ ~ 15 ℃ refrigerator) |
PCR Supplies/Consumables | Compatible with 0.1mL and 0.2mL 8-tube strips, and 96-well plates; |
Contamination Control Design | (1) Separate, enclosed nucleic acid extraction space, with directional top ventilation to create an internal negative pressure system; (2) Sample loading device equipped with airtight, drip-proof design. (3) External droplet capture tray; (4) UV light sterilization units for the experimental and extraction cabinets; (5) Customized function: bottom ventilation of the nucleic acid extraction area available by special ventilation circuit design. |
Information technology | (1) Multiple sample barcodes are scanned one by one during sample rack loading. (2) Identification of the extraction kit barcode, and automatic parsing of the extraction program information. (4) Identification of PCR kit component barcode, and automatic parsing of amplification program information. (5) Automatic parsing of PCR information and LIS connection, based on nucleic acid extraction data. |
Operation | Embedded 12-inch touch screen; multi-module real-time status light |
Size and Weight | 1370mm x 810mm x 890mm (W*D*H), 220 kg |
Power | AC 220± 20 V, 50/60 Hz. |