DIKAI DK-40 2 Poles Type 2 Single Phase Surge Protective Device 220V AC 275V Surge Arrestors
Negotiable
Min.Order:1
AC Power Surge Protector,Signal Surge Protective Device for Lightning Protection 40ka 2p 1+1
OEM factory type 1 2 spd type 1 2 100ka spd protector de voltaje 220 for home
SPD 1000V 20KA~40KA dc surge arrester lightning dc power surge protector
SPD 1000V 20KA~40KA dc cat 5 surge protection lightning dc power surge protector
DK lightning protection 220 vac surge protector usa modular spd 20ka
Indication Window Surge Protection Device SPD DK-DC20 DC 48V 110V SPD with 35mm Din Rail Mounted
DIKAI DK-40 2 Poles Type 2 Single Phase Surge Protective Device 220V AC 275V Surge Arrestors
Specification
1) Product Type: 40kA Single Phase Single Phase Single Phase Surge Arrestors
2) Power System: 220V, 275V, 380V, AC Power Supply Single Phase Power System
3) Rated Voltage: 220V AC(Can be customized according to client's request)
4) Nominal Discharge Current(8/20): 10kA, 20kA, 30kA, 40kA, 50kA, 60kA Selection
5) Maximum Discharge Current(8/20):20kA, 40kA, 60kA, 80kA, 100kA, 160kA Selection
6) Protection Mode: L-PE,N-PE(2P), 1+1P, L-PE,N-PE(4P), 3+1P Selection
7) Voltage Protection (8/20): Less than 1.5kV
8) Production Standard: IEC61643-1
9) Indication Method: Window Indicator
SPD Type | DK-40 2P IP20 Class II 2 Poles Type 2 Single Phase 40kA 220V AC 275V Surge Arrestors |
Applicable Power Supply System | TT, TN, IT |
Maximum Continuous Operating Voltage Uc | AC 385V |
Nominal Discharge Current (8/20µs) | 20kA |
Maximum Discharge Current (8/20µs) | 40kA |
Voltage Protection Level Up | ≤1.8kV |
Leakage Current | ≤20uA |
Respond Time tA | ≤25ns |
Indication Method | Indication Window, Turn Red When Malfunction |
Remote Alarm Function | Available |
Maximum Connection Wire Range |
BVR 25mm2 |
Method of Installation |
35mm Din Rail Mounted |
Material of Shell |
PC |
Protection Level of Outer Shell |
IP20 |
Working Temperature | –25~+70℃ |
Relative Humidity |
≤95%RH |
Item No. Selection
Item Series | Protection Mode | Installation Location | Dimension(mm) | Item No. |
DK-40 |
L-PE, N-PE(2P) L-PE, N-PE(1+1P) |
Low-voltage Single Phase Power Distribution Cabinet | 36*91*66mm |
DK-40 2P DK-40(1+1P) |
L-PE, N-PE(4P) L-PE, N-PE(3+1P) |
Low-voltage Three Phase Power Distribution Cabinet | 72*91*66mm |
DK-40 4P DK-40(3+1P) |
Application Scope
It can be installed in the low voltage power distribution cabinet/box of buildings, to protect all kinds of power equipment in the single (three) phase power distribution system between LPZ1 and LPZ2.
Installation and Caution