DK-20 2P 2 Poles Single Phase 275V AC Power SPD Protector Surge Protection Device
Negotiable
Min.Order:1
Dikai Factory 3P 20kA lightning surge protector low voltage 385v supressor
12.5kA 380V 3P 3 Poles Class I SPD lightning Power AC Surge Protective Device
Din Rail AC 380V Imax 40kA 220V Power Supply Surge Protector Device /spd /surge protector
DK 20 4P low voltage lightning surge arrester SPD voltage surge protector AC power line protection
Surge Protective Device 100KA Thunder Lightning Protector manufacturers surge protection device
2. Technical Parameter
SPD Type |
DK-20 2P 2 Poles Single Phase 275V AC Power SPD Protector Surge Protection Device
|
Applicable Power Supply System |
TT, TN, IT Power Supply System |
Maximum Continuous Operating Voltage Uc |
AC 385V |
Nominal Discharge Current (8/20µs) |
10kA |
Maximum Discharge Current (8/20µs) |
25kA |
Voltage Protection Level Up |
≤1.5kV |
≤1.1kV(8/20µs,5kA) |
|
Leakage Current |
≤20uA |
Respond Time tA |
≤25ns |
Indication Method |
Indication Window, Turn Red When Malfunction |
Remote Alarm Function |
Optional |
Maximum Connection Wire Range |
BVR 25mm2 |
Method of Installation |
35mm Din Rail Mounted |
Material of Shell |
PC |
Flame Retardant Rating of Outer Shell |
UL94-V0 |
Protection Level of Outer Shell |
IP20 |
Working Temperature |
–25~+70℃ |
Relative Humidity |
≤95%RH |
3. Item Number
Item Series |
Protection Mode |
Installation Location |
Dimension(mm) |
Item No. |
DK-20 |
L-PE, N-PE(2P) |
Low-voltage Single Phase Power Distribution Cabinet |
36*91*66mm |
DK-20 2P |
L-N-PE(1+1P) |
DK-20(1+1) |
|||
L-PE, N-PE(4P) |
Low-voltage Three Phase Power Distribution Cabinet |
72*91*66mm |
DK-20 4P |
|
L-N-PE(3+1P) |
DK-20(3+1) |
4. Application Scope
It can be installed in the low voltage power distribution cabinet/box of buildings, to protect all kinds of power equipment in the single (three) phase power distribution system between LPZ1 and LPZ2. Such as:
1) Low voltage general electricity cabinet and or distribution board of buildings.
2) Outdoor electricity cabinet/distribution box.
3) Applicable power supply system: TT, TN, IT.
5. External View
6. Installation and Caution
1) DK-20 modular surge protective device(SPD) can be installed in any place of the single phase AC power line, and mostly be installed in power distribution boxes, power switches and sockets. It shall be connected with the power line in parallel, and shall adopt Kevin Connection, so as to lower the residual voltage.
2) Strip away the surface rubber of input and output terminal, and expose the copper core. Insert the copper core into the hole of the SPD, and make it firm with a screwdriver.
3) The cross-section of the grounding conductor connected with the module SPD indicating alarm shall be at least 16mm2, and the lead wire of the grounding conductor shall be shorter than 1m, and the shorter the better.