Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P
Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P
Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P
Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P
Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P

Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P

Negotiable

Min.Order:1

Supply Ability:
1000 per Month
Payment Terms:
T/T Credit Card

Guangxi Dikai Sci & Tech Co., Ltd.

Business Type: Distributor/Wholesaler
Main Products: , , ,

Product Details

Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P

Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P

Specification of Type 2 Surge Protection Device 2P

1. Product Type: Din Rail 25kA Type 2 SPD 2 Pole Surge Protection Device 2P

2. Power System: 220V Single Phase Power System

3. Rated Voltage: 220V AC(Can be customized according to client's request)

4. Nominal Discharge Current(8/20): 10kA, 20kA, 30kA, 40kA, 50kA, 60kA Selection

5. Maximum Discharge Current(8/20):20kA, 40kA, 60kA, 80kA, 100kA, 160kA Selection

6. Protection Mode: L-PE,N-PE(2P), 1+1P, L-PE,N-PE(4P), 3+1P Selection

7. Voltage Protection (8/20): Less than 1.5kV

8. Production Standard: IEC61643-1

9. Indication Method: Window Indicator

Description of Type 2 Surge Protection Device 2P
  DK-20 Type 2 Surge Protection Device 2P is designed according to IEC61643 standard. It is accordance with the criterion of Low-voltage Surge Protective Devices-Part 1: Surge Protective Devices Performance Requirements and Test Method of Low-voltage Power Distribution System. With good sealing, it is designed as module and 35mm DIN-Rail Mounting. With working indication window, temperature control circuit breaker and built-in over-current protective circuit, the modular SPD can release automatically to avoid fire danger when it breaks down. With remote alarm connector, it is convenient for remote monitoring. The main module and the base are replaceable. The lightning protection modes is L-PE, N-PE (2P/4P) or L-N-PE (1+1P) / (3+1P).

Technical Parameter of Type 2 Surge Protection Device 2P

SPD Type One-port Type 2 Surge Protection Device 2P
Applicable Power Supply System TT, TN, IT
Maximum Continuous Operating Voltage Uc AC 385V
Nominal Discharge Current (8/20µs) 10kA
Maximum Discharge Current (8/20µs) 25kA
Voltage Protection Level Up ≤1.5kV
Leakage Current ≤20uA
Respond Time tA ≤25ns
Indication Method Indication Window, Turn Red When Malfunction
Remote Alarm Function Available

Maximum Connection Wire Range

BVR 25mm2

Method of Installation

25mm Din Rail Mounted

Material of Shell

PC

Protection Level of Outer Shell

 IP20
Working Temperature –25~+70℃

Relative Humidity

 95%RH

 

Item No. Selection for thisType 2 Surge Protection Device 2P

Item Series Protection Mode Installation Location Dimension(mm) Item No.
DK-20

L-PE, N-PE(2P)

L-PE, N-PE(1+1P)

Low-voltage Single Phase Power Distribution Cabinet 36*91*66mm

DK-20 2P

DK-20(1+1P)

L-PE, N-PE(4P)

L-PE, N-PE(3+1P)

Low-voltage Three Phase Power Distribution Cabinet 72*91*66mm

DK-20 4P

DK-20(3+1P)

 


Application Scope of the Type 2 Surge Protection Device 2P

  It can be installed in the low voltage power distribution cabinet/box of buildings, to protect all kinds of power equipment in the single (three) phase power distribution systembetween LPZ1 and LPZ2. Such as:

1) Low voltage general electricity cabinet and or distribution board of buildings.

2) Outdoor electricity cabinet/distribution box.

3) Applicable power supply system: TT, TN, IT.

 

Installation and Caution for this Type 2 Surge Protection Device 2P

Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P

 1) DK-20 Type 2 Surge Protection Device 2P can be installed in any place of the single phase AC power line, and mostly be installed in power distribution boxes, power switches and sockets. It shall be connected with the power line in parallel, and shall adopt Kevin Connection, so as to lower the residual voltage.

 2) Strip away the surface rubber of input and output terminal, and expose the copper core. Insert the copper core into the hole of the SPD, and make it firm with a screwdriver.

 3) The cross-section of the grounding conductor connected with the module SPD indicating alarm shall be at least 16mm2, and the lead wire of the grounding conductor shall be shorter than 1m, and the shorter the better.

Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2PDin Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2PDin Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P

 

related products
Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P
Lightning Rod Series Signal Series SPD lightning strike counter
Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P
LED street light SPD Monitoring System SPD Antenna Feeder SPD
Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P 
Grounding Series extension socket  CCTV canera surge protector 

 

Our Services

Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2PDin Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2PDin Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2PDin Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P 

FAQ

Din Rail Imax 25kA Type 2 SPD 2 Pole Surge Protection Device 2P 

Contact Supplier

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Power Distribution Equipment