Hot Sale Low Voltage 0.6/1kv 150mm Aluminum Abc Cables Conductor Overhead Strand Abc Cable
Negotiable
Min.Order:1
Henan Kingyear Aluminum Industrial Co., Ltd.
High Quality Abc Cable 95mm China Henan Supplier Abc Conductor
Low Voltage 0.6/1kv Abc Aerial Bundled Cable With Best Quality Price
Low Voltage 0.6/1kv Abc Aerial Bundle Cable JKLYJ Aluminium Abc Overhead Cable
Low Voltage 3*50mm2 Abc Cable Insulated Multi-Core Stranded Abc Cable In Low Price
Cables Aluminium 1x70 Mm2+ 3x70 Mm2 Abc Cable Insulation Sheath Abc Cable
Overhead Aerial Bundle Low Voltage Aluminium Xlpe Insulated Abc Cable Good Price
ABC Cable-DES/LVC IEC 60502 (AL/XLPE) | ||||||||
umber of cores x nominal cross section | min. breaking load of conductor strand | Current rating in the air | Outer diameter | Total weight | ||||
mm² | kN | A | mm | kg/km | ||||
4x25 RM | 3.5 | 84 | 21.5 | 420 | ||||
4x35 RM | 4.9 | 104 | 23.9 | 550 | ||||
4x120+1x25 RM | 16.8 | 246 | 43.8 | 1800 | ||||
4x185+1x25 RM | 25.9 | 332 | 50.7 | 2700 |
ABC Cable-AS/NZS 3560.1 Stansard | ||||||||
Number of cores x nominal cross section | min. breaking load of conductor strand | Current rating in the air | Outer diameter | Total weight | ||||
mm² | kN | A | mm | kg/km | ||||
2x16 RM | 4.4 | 78 | 15 | 140 | ||||
2x25 RM | 7 | 105 | 17.6 | 210 | ||||
2x35 RM | 9.8 | 125 | 19.6 | 270 | ||||
2x50 RM | 11.4 | 150 | 22.8 | 370 | ||||
2x95 RM | 15.3 | 230 | 30.6 | 680 | ||||
3x25 RM | 8.8 | 97 | 19 | 310 | ||||
3x35 RM | 9.8 | 120 | 21.1 | 410 | ||||
3x50 RM | 11.4 | 140 | 24.6 | 550 | ||||
4x16 RM | 8.8 | 74 | 18.1 | 290 | ||||
4x25 RM | 14 | 97 | 21.2 | 410 | ||||
4x35 RM | 19.6 | 120 | 23.7 | 550 | ||||
4x50 RM | 28 | 140 | 27.5 | 740 | ||||
4x70 RM | 39.2 | 175 | 31.9 | 1000 | ||||
4x95 RM | 53.2 | 215 | 36.9 | 1370 | ||||
4x120 RM | 67.2 | 250 | 40.6 | 1690 | ||||
4x150 RM | 84 | 280 | 43.9 | 2020 |
Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | ||||||||||||||
Size & No.of wires | Insulation Thick (mm) | Nominal Dia.(mm) | Size & No.of wires | Rated Strength (kg) | XLPE (kg/km) | Al. | ( A ) | |||||||||||
Bare (mm) | OD (mm) | |||||||||||||||||
AAC | ||||||||||||||||||
Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 | |||||||||
Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 | |||||||||
Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 | |||||||||
Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 | |||||||||
Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 | |||||||||
Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 | |||||||||
Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 | |||||||||
Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | - | 56.5 | 233.6 | 158 | |||||||||
Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
AAAC | ||||||||||||||||||
Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 | |||||||||
VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 | |||||||||
Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 | |||||||||
Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 | |||||||||
Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 | |||||||||
Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
ACSR | ||||||||||||||||||
Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 | |||||||||
Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 | |||||||||
Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 | |||||||||
Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 | |||||||||
Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 | |||||||||
Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 | |||||||||
Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 | |||||||||
Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 | |||||||||
Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Duplex Service Drop ABC Cable Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting.For service at 600 volts or lower at a conductor temperature of 75°C maximum. | ||||||||||||||||||
Triplex Service Drop ABC Cable Application: To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation. | ||||||||||||||||||
Quadruplex Service Drop. ABC Cable Applications:Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors. |