2*16 Twisted Service Drop Cables Xlpe Insulated Aluminum Conductor Cable Abc Cable
Negotiable
Min.Order:1
Henan Kingyear Aluminum Industrial Co., Ltd.
High Quality 2 Cores XLPE Insulated Abc Cable Harrier Whippet Abc Cable Duplex Manufactures
4 Core Abc Power Cable 95mm Abc Cable Economical/Convenient Overhead Abc Cable
0.6/1kv 3 Core Aluminum Xlpe Insulated Abc Cable With Service Connection
Low Voltage 600v Triplex Cable Overhead Abc Cable Price List
ABC Cable-DES/LVC IEC 60502 (AL/XLPE) | ||||||||
umber of cores x nominal cross section | min. breaking load of conductor strand | Current rating in the air | Outer diameter | Total weight | ||||
mm² | kN | A | mm | kg/km | ||||
4x25 RM | 3.5 | 84 | 21.5 | 420 | ||||
4x35 RM | 4.9 | 104 | 23.9 | 550 | ||||
4x120+1x25 RM | 16.8 | 246 | 43.8 | 1800 | ||||
4x185+1x25 RM | 25.9 | 332 | 50.7 | 2700 |
ABC Cable-AS/NZS 3560.1 Stansard | ||||||||
Number of cores x nominal cross section | min. breaking load of conductor strand | Current rating in the air | Outer diameter | Total weight | ||||
mm² | kN | A | mm | kg/km | ||||
2x16 RM | 4.4 | 78 | 15 | 140 | ||||
2x25 RM | 7 | 105 | 17.6 | 210 | ||||
2x35 RM | 9.8 | 125 | 19.6 | 270 | ||||
2x50 RM | 11.4 | 150 | 22.8 | 370 | ||||
2x95 RM | 15.3 | 230 | 30.6 | 680 | ||||
3x25 RM | 8.8 | 97 | 19 | 310 | ||||
3x35 RM | 9.8 | 120 | 21.1 | 410 | ||||
3x50 RM | 11.4 | 140 | 24.6 | 550 | ||||
4x16 RM | 8.8 | 74 | 18.1 | 290 | ||||
4x25 RM | 14 | 97 | 21.2 | 410 | ||||
4x35 RM | 19.6 | 120 | 23.7 | 550 | ||||
4x50 RM | 28 | 140 | 27.5 | 740 | ||||
4x70 RM | 39.2 | 175 | 31.9 | 1000 | ||||
4x95 RM | 53.2 | 215 | 36.9 | 1370 | ||||
4x120 RM | 67.2 | 250 | 40.6 | 1690 | ||||
4x150 RM | 84 | 280 | 43.9 | 2020 |
Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | ||||||||||||||
Size & No.of wires | Insulation Thick (mm) | Nominal Dia.(mm) | Size & No.of wires | Rated Strength (kg) | XLPE (kg/km) | Al. | ( A ) | |||||||||||
Bare (mm) | OD (mm) | |||||||||||||||||
AAC | ||||||||||||||||||
Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 | |||||||||
Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 | |||||||||
Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 | |||||||||
Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 | |||||||||
Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 | |||||||||
Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 | |||||||||
Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 | |||||||||
Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | - | 56.5 | 233.6 | 158 | |||||||||
Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 | |||||||||
AAAC | ||||||||||||||||||
Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 | |||||||||
VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 | |||||||||
Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 | |||||||||
Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 | |||||||||
Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 | |||||||||
Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 | |||||||||
ACSR | ||||||||||||||||||
Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 | |||||||||
Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 | |||||||||
Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 | |||||||||
Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 | |||||||||
Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 | |||||||||
Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 | |||||||||
Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 | |||||||||
Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 | |||||||||
Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 | |||||||||
Duplex Service Drop ABC Cable Application:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting.For service at 600 volts or lower at a conductor temperature of 75°C maximum. | ||||||||||||||||||
Triplex Service Drop ABC Cable Application: To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation. | ||||||||||||||||||
Quadruplex Service Drop. ABC Cable Applications:Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors. |